Loss of the Correct Quantity in the Blue Hydraulic Reservoir
TASK 29-12-00-810-803-A
Loss of the Correct Quantity in the Blue Hydraulic Reservoir
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-12-00-865-052-A
Subtask 29-12-00-810-071-A
[Rev.8 from Aug 2018]
2026.04.04 04:39:55 UTC
Loss of the Correct Quantity in the Blue Hydraulic Reservoir
1. Possible Causes
- LOW LEVEL SWITCH
- wiring
DIODE (1156VD) - QUANTITY INDICATOR - TRANSMITTER
- hydraulic lines
- SDAC-1 [1WV1]
- SDAC-2 [1WV2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-54-00-810-831-A | Loss of the BLUE RSVR QTY Input of the SDAC 1 |
| TSM TASK 31-54-00-810-832-A | Loss of the BLUE RSVR QTY Input of the SDAC 2 |
| AMM 12-32-28-281-001 | Drain Water Content |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 29-00-00-280-002 | Check of the Internal Leakage of the Blue Hydraulic System |
| AMM 29-00-00-790-001 | Check of the External Leaks of the Hydraulic Components |
| ASM 291201 | |
| AMM 29-12-41-000-002 | Removal of the Quantity Indicator of the Blue Hydraulic Reservoir |
| AMM 29-12-41-000-003 | Removal of the Low Level Switch of the Blue Hydraulic Reservoir |
| AMM 29-12-41-400-002 | Installation of the Quantity Indicator of the Blue Hydraulic System |
| AMM 29-12-41-400-003 | Installation of the Low Level Switch of the Blue Hydraulic System |
| AMM 29-31-00-710-001 | Functional Check of Reservoir Low Level Warning |
| ASM 293101 | |
| ASM 293102 | |
| ASM 315401 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| AMM 31-60-00-860-001 | EIS Start Procedure |
Subtask 29-12-00-865-052-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-12-00-860-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
| 121VU | HYDRAULIC/LOW/LVL/IND | 1832GQ | N32 |
| 121VU | HYDRAULIC/HYD/QTY/IND | 1831GQ | P35 |
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) On the ECAM control panel on the center pedestal, push the HYD pushbutton switch. Make sure that the HYD page is shown on the system display of the ECAM.
(4) Look for fault indications on the upper ECAM DU, the lower ECAM DU and panel 40VU.
4. Fault Isolation(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) On the ECAM control panel on the center pedestal, push the HYD pushbutton switch. Make sure that the HYD page is shown on the system display of the ECAM.
(4) Look for fault indications on the upper ECAM DU, the lower ECAM DU and panel 40VU.
Subtask 29-12-00-810-071-A
A. If the Fault Confirmation gives:
(2) If the quantity shown is more than or equal to 2.4 l (0.6340 USgal):
(a) Do a check for 28 VDC between:
1 Do a check of the wiring between:
1 Replace the LOW LEVEL SWITCH AMM 29-12-41-000-003 and AMM 29-12-41-400-003.
(d) If the fault continues:
1 Make sure that the wiring is not connected to GND between:
1 Do a check of the internal leakage of the Blue hydraulic system AMM 29-00-00-280-002.
2 If the internal leakage rate is too high:
a Take a fuel sample from each water drain-valve AMM 12-32-28-281-001.
b Do a check for contamination of the fuel with hydraulic fluid after each removal of a fuel sample.
c If you find hydraulic fluid contamination in one or more fuel samples:
Subtask 29-12-00-810-072-A - The message HYD B RSVR LO LVL on the upper ECAM DU
- The contents indication (shows low-fluid level) on the lower ECAM DU in amber
- The BLUE ELEC PUMP P/BSW FAULT on panel 40VU
- The single chime and the MASTER CAUT lights come on.
(2) If the quantity shown is more than or equal to 2.4 l (0.6340 USgal):
(a) Do a check for 28 VDC between:
- LOW LEVEL SWITCH connector B/A and connector B/C ASM 293102.
1 Do a check of the wiring between:
- LOW LEVEL SWITCH connector B/C and CB (1832GQ) and repair the wiring as necessary ASM 293102.
1 Replace the LOW LEVEL SWITCH AMM 29-12-41-000-003 and AMM 29-12-41-400-003.
(d) If the fault continues:
1 Make sure that the wiring is not connected to GND between:
- LOW LEVEL SWITCH connector B/B and
DIODE (1156VD) connector 15 ASM 291201 and ASM 293101.
- Repair the wiring as necessary.
- Replace the the QUANTITY INDICATOR - TRANSMITTER AMM 29-12-41-000-002 and AMM 29-12-41-400-002.
- Make sure that the drain valve of the hydraulic reservoir has no leaks.
- Replace the drain valve.
- Do a check of the hydraulic lines and the components for leaks AMM 29-00-00-790-001 and repair them.
1 Do a check of the internal leakage of the Blue hydraulic system AMM 29-00-00-280-002.
2 If the internal leakage rate is too high:
- Repair the defective component.
a Take a fuel sample from each water drain-valve AMM 12-32-28-281-001.
b Do a check for contamination of the fuel with hydraulic fluid after each removal of a fuel sample.
c If you find hydraulic fluid contamination in one or more fuel samples:
- Do a check of the hydraulic lines and components in the applicable tank area for leaks and repair them.
B. If the Fault Confirmation gives:
(2) If the quantity shown is more than or equal to 1.8 l (0.4755 USgal):
(a) Do a check for 26 VAC between:
a Do a check of the wiring between:
a Do a check for a ground signal between:
1 Do the troubleshooting procedure for the loss of the BLUE RSVR QTY input of the SDAC-1 [1WV1] (Ref. TSM TASK 31-54-00-810-831).
2 If the fault continues:
a Do the troubleshooting procedure for the loss of the BLUE RSVR QTY input of the SDAC-2 [1WV2] (Ref. TSM TASK 31-54-00-810-832).
(3) If the quantity shown is less than or equal to 2.0 l (0.5283 USgal):
(a) Do a check for 28 VDC at:
1 Do a check of the wiring between:
1 Replace the LOW LEVEL SWITCH AMM 29-12-41-000-003 and AMM 29-12-41-400-003.
(d) If the fault continues:
1 Make sure that the wiring is not connected to GND between:
(a) If the drain valve has a leak:
a Take a fuel sample from each water drain-valve AMM 12-32-28-281-001.
b Do a check for contamination of the fuel with hydraulic fluid after each removal of a fuel sample.
c If you find hydraulic fluid contamination in one or more fuel samples:
Subtask 29-12-00-810-054-A - The message HYD B RSVR LO LVL on the upper ECAM DU
- The contents indication (shows low fluid level) on the lower ECAM DU in amber.
(2) If the quantity shown is more than or equal to 1.8 l (0.4755 USgal):
(a) Do a check for 26 VAC between:
- QUANTITY INDICATOR - TRANSMITTER connector A/D and connector A/E ASM 293101.
a Do a check of the wiring between:
- QUANTITY INDICATOR - TRANSMITTER connector A/D and CB (1831GQ) and repair the wiring as necessary ASM 293101.
a Do a check for a ground signal between:
- QUANTITY INDICATOR - TRANSMITTER connector A/E and ground ASM 293101.
- Repair the wiring between QUANTITY INDICATOR - TRANSMITTER connector A/E and ground ASM 293101.
- Replace the QUANTITY INDICATOR - TRANSMITTER AMM 29-12-41-000-002 and AMM 29-12-41-400-002.
1 Do the troubleshooting procedure for the loss of the BLUE RSVR QTY input of the SDAC-1 [1WV1] (Ref. TSM TASK 31-54-00-810-831).
2 If the fault continues:
a Do the troubleshooting procedure for the loss of the BLUE RSVR QTY input of the SDAC-2 [1WV2] (Ref. TSM TASK 31-54-00-810-832).
(3) If the quantity shown is less than or equal to 2.0 l (0.5283 USgal):
(a) Do a check for 28 VDC at:
- LOW LEVEL SWITCH connector B/C ASM 293102.
1 Do a check of the wiring between:
- LOW LEVEL SWITCH connector B/C and CB (1832GQ) and repair the wiring as necessary ASM 293102.
1 Replace the LOW LEVEL SWITCH AMM 29-12-41-000-003 and AMM 29-12-41-400-003.
(d) If the fault continues:
1 Make sure that the wiring is not connected to GND between:
- LOW LEVEL SWITCH connector B/B and
DIODE (1156VD) connector 15 ASM 291201 and ASM 293101.
- Repair the wiring as necessary.
(a) If the drain valve has a leak:
- Replace the drain valve.
- Do a check of the hydraulic lines and components for leaks AMM 29-00-00-790-001 and repair them.
- Do a check of the internal leakage of the Blue hydraulic system AMM 29-00-00-280-002.
- Repair the defective component.
a Take a fuel sample from each water drain-valve AMM 12-32-28-281-001.
b Do a check for contamination of the fuel with hydraulic fluid after each removal of a fuel sample.
c If you find hydraulic fluid contamination in one or more fuel samples:
- Do a check of the hydraulic lines and components in the applicable tank area for leaks and repair them.
C. If the Fault Confirmation gives:
(2) If the quantity shown is less than 1.8 l (0.4755 USgal):
(a) Replace the QUANTITY INDICATOR - TRANSMITTER AMM 29-12-41-000-002 and AMM 29-12-41-400-002.
(3) Make sure that the drain valve of the hydraulic reservoir has no leaks.
(a) If the drain valve has a leak:
1 Replace the drain valve.
(b) If the drain valve has no leaks:
1 Do a check of the hydraulic lines and components for leaks AMM 29-00-00-790-001 and repair them.
(c) If the fault continues:
1 Do a check of the internal leakage of the Blue hydraulic system AMM 29-00-00-280-002.
2 If the internal leakage rate is too high:
a Repair the defective component.
3 If the fault continues, or you can not find a defective component:
a Take a fuel sample from each water drain-valve AMM 12-32-28-281-001,
b Do a check for contamination of the fuel with hydraulic fluid after each removal of a fuel sample.
4 If you find hydraulic fluid contamination in one or more fuel samples:
a Do a check of the hydraulic lines and components in the applicable tank area for leaks and repair them.
Subtask 29-12-00-810-065-A - The message HYD B RSVR LO LVL on the upper ECAM DU
- The BLUE ELEC PUMP P/BSW FAULT on panel 40VU
- The single chime and the MASTER CAUT lights come on.
(2) If the quantity shown is less than 1.8 l (0.4755 USgal):
(a) Replace the QUANTITY INDICATOR - TRANSMITTER AMM 29-12-41-000-002 and AMM 29-12-41-400-002.
(3) Make sure that the drain valve of the hydraulic reservoir has no leaks.
(a) If the drain valve has a leak:
1 Replace the drain valve.
(b) If the drain valve has no leaks:
1 Do a check of the hydraulic lines and components for leaks AMM 29-00-00-790-001 and repair them.
(c) If the fault continues:
1 Do a check of the internal leakage of the Blue hydraulic system AMM 29-00-00-280-002.
2 If the internal leakage rate is too high:
a Repair the defective component.
3 If the fault continues, or you can not find a defective component:
a Take a fuel sample from each water drain-valve AMM 12-32-28-281-001,
b Do a check for contamination of the fuel with hydraulic fluid after each removal of a fuel sample.
4 If you find hydraulic fluid contamination in one or more fuel samples:
a Do a check of the hydraulic lines and components in the applicable tank area for leaks and repair them.
D. If the Fault Confirmation gives:
(2) If the quantity shown on the indicator is normal:
(a) Remove the SDAC-1 [1WV1] and SDAC-2 [1WV2] AMM 31-55-34-000-001.
(b) Remove the connector from the LOW LEVEL SWITCH.
(c) Do a check of the wiring for a ground signal between:
1 The LOW LEVEL SWITCH connector B/B and the SDAC-1 [1WV1] SDAC1 connector AA/3E ASM 293101 and ASM 315401.
a If there is a ground signal, repair the wiring.
(d) Install the SDAC-1 [1WV1] and SDAC-2 [1WV2] AMM 31-55-34-400-001.
(e) Install the connector of the LOW LEVEL SWITCH.
(3) If there is no ground signal or the fault continues:
Subtask 29-12-00-710-053-A - The message HYD B RSVR LO LVL on the upper ECAM DU
- The contents indication (shows normal fluid level) on the lower ECAM DU in green
- The BLUE ELEC PUMP P/BSW FAULT on panel 40VU
- The single chime and the MASTER CAUT lights come on.
(2) If the quantity shown on the indicator is normal:
(a) Remove the SDAC-1 [1WV1] and SDAC-2 [1WV2] AMM 31-55-34-000-001.
(b) Remove the connector from the LOW LEVEL SWITCH.
(c) Do a check of the wiring for a ground signal between:
1 The LOW LEVEL SWITCH connector B/B and the SDAC-1 [1WV1] SDAC1 connector AA/3E ASM 293101 and ASM 315401.
a If there is a ground signal, repair the wiring.
(d) Install the SDAC-1 [1WV1] and SDAC-2 [1WV2] AMM 31-55-34-400-001.
(e) Install the connector of the LOW LEVEL SWITCH.
(3) If there is no ground signal or the fault continues:
- Replace the LOW LEVEL SWITCH AMM 29-12-41-000-003 and AMM 29-12-41-400-003.