Overheat Indication of the Blue Hydraulic System
TASK 29-12-00-810-802-A
Overheat Indication of the Blue Hydraulic System
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 29-12-00-865-051-A
Subtask 29-12-00-810-051-A ** ON A/C NOT FOR ALL
Subtask 29-12-00-860-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:21 UTC
Overheat Indication of the Blue Hydraulic System
1. Possible Causes
- internal leakage
- RELIEF VALVE B SYS [2063GM]
- LP FILTER B [2002GM]
- HP-FILTER B [2048GM]
[2059GM] - CHECK VALVE G [2022GM]
- CHECK VALVE B [2050GM]
- CASE DRAIN FILT.ELEC.PUMP B [2084GM]
- MANIFOLD SWITCH PRESSURE [2380GM]
TEMP TRANSM SWITCH-connector plug (2381GR-A) - TEMP TRANSM SWITCH [2381GR]
- SDAC-1 [1WV1]
- SDAC-2 [1WV2]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | OHMMETER MODEL 260 |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 29-00-00-280-002 | Check of the Internal Leakage of the Blue Hydraulic System |
| AMM 29-00-00-910-003 | General Removal and Installation Procedure of the Check Valves in the Hydraulic Systems |
| AMM 29-10-00-863-003 | Pressurize the Blue Hydraulic System with a Hydraulic Ground Power-Cart |
| AMM 29-10-00-864-003 | Depressurize the Blue Hydraulic System |
| ASM 291201 | |
| AMM 29-12-32-000-001 | Removal of the Pressure Relief Valve of the Blue Hydraulic System |
| AMM 29-12-32-400-001 | Installation of the Pressure Relief Valve of the Blue Hydraulic System |
| AMM 29-12-43-610-001 | Servicing of the Electric-Pump Case-Drain Filter |
| AMM 29-12-44-610-001 | Servicing of the LP-Filter |
| AMM 29-12-45-610-001 | Servicing of the HP-Filter |
| ASM 293301 | |
| AMM 29-33-11-000-002 | Removal of the Temperature Transmitter |
| AMM 29-33-11-400-002 | Installation of the Temperature Transmitter |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| AMM 31-60-00-860-001 | EIS Start Procedure |
Subtask 29-12-00-865-051-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-12-00-710-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
B. Test
AMM 24-41-00-861-002.
(2) Pressurize the Blue hydraulic system with the electric pump AMM 29-10-00-863-003.
(3) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(4) Operate the sidestick for ailerons, spoilers and elevators at full travel for 5 min.
(5) Operate the rudder pedals at full travel for 5 min.
(6) Operate the flap and slat control lever at full travel for 5 min.
4. Fault IsolationWARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
(1) Energize the aircraft electrical circuitsAMM 24-41-00-861-002.
(2) Pressurize the Blue hydraulic system with the electric pump AMM 29-10-00-863-003.
(3) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(4) Operate the sidestick for ailerons, spoilers and elevators at full travel for 5 min.
(5) Operate the rudder pedals at full travel for 5 min.
(6) Operate the flap and slat control lever at full travel for 5 min.
Subtask 29-12-00-810-051-A ** ON A/C NOT FOR ALL
A. If the test gives:
(a) If the internal leakage is more than permitted:
1 Do a check of the filter elements of the CASE DRAIN FILT.ELEC.PUMP B [2084GM] , HP-FILTER B [2048GM] and LP FILTER B [2002GM] .
2 Replace the filter element as necessary AMM 29-12-43-610-001 or AMM 29-12-45-610-001 or AMM 29-12-44-610-001.
Subtask 29-12-00-810-051-B ** ON A/C NOT FOR ALL - The message HYD B RSVR OVHT on the upper ECAM DU
- The BLUE ELEC PUMP P/BSW FAULT light on panel 40VU
- The OVHT flag on the HYD page of the lower ECAM DU.
NOTE: The fault warning system shows, that the temperature is more than 95 +2.2 deg.C or -2.2 deg.C (203.00 +3.96 deg.F or -3.96 deg.F). This was detected by the temperature (TEMP) transducers (XDCRs) and the thermal switch of the reservoir (RSVR) TEMP sensor FIN 2381GR.
(1) Do a check of the internal leakage of the Blue hydraulic system AMM 29-00-00-280-002. (a) If the internal leakage is more than permitted:
- Examine the system to find the defective component
- Replace or repair the defective component.
- RELIEF VALVE B SYS [2063GM] AMM 29-12-32-000-001 AMM 29-12-32-400-001
- LP FILTER B [2002GM] AMM 29-12-44-610-001
- HP-FILTER B [2048GM] AMM 29-12-45-610-001
[2059GM] AMM 29-00-00-910-003 - CHECK VALVE G [2022GM] AMM 29-00-00-910-003.
NOTE: If for fault duplication the system is pressurized by a ground power cart, it is necessary to examine also the CHECK VALVE B [2050GM] .
(b) If the internal leakage is in the given limits: 1 Do a check of the filter elements of the CASE DRAIN FILT.ELEC.PUMP B [2084GM] , HP-FILTER B [2048GM] and LP FILTER B [2002GM] .
2 Replace the filter element as necessary AMM 29-12-43-610-001 or AMM 29-12-45-610-001 or AMM 29-12-44-610-001.
A. If the test gives:
(a) If the internal leakage is more than permitted:
1 Do a check of the filter elements of the CASE DRAIN FILT.ELEC.PUMP B [2084GM] , HP-FILTER B [2048GM] and LP FILTER B [2002GM] .
2 Replace the filter element as necessary AMM 29-12-43-610-001 or AMM 29-12-45-610-001 or AMM 29-12-44-610-001.
Subtask 29-12-00-810-078-A - The message HYD B RSVR OVHT on the upper ECAM DU
- The BLUE ELEC PUMP P/BSW FAULT light on panel 40VU
- The OVHT flag on the HYD page of the lower ECAM DU.
NOTE: The fault warning system shows, that the temperature is more than 95 +2.2 deg.C or -2.2 deg.C (203.00 +3.96 deg.F or -3.96 deg.F). This was detected by the temperature (TEMP) transducers (XDCRs) and the thermal switch of the reservoir (RSVR) TEMP sensor FIN 2381GR.
(1) Do a check of the internal leakage of the Blue hydraulic system AMM 29-00-00-280-002. (a) If the internal leakage is more than permitted:
- Examine the system to find the defective component
- Replace or repair the defective component.
- RELIEF VALVE B SYS [2063GM] AMM 29-12-32-000-001 AMM 29-12-32-400-001
- LP FILTER B [2002GM] AMM 29-12-44-610-001
- HP-FILTER B [2048GM] AMM 29-12-45-610-001
[2059GM] AMM 29-00-00-910-003 - CHECK VALVE G [2022GM] AMM 29-00-00-910-003.
NOTE: If for fault duplication, the system is pressurized by a ground power cart, it is necessary to examine also the MANIFOLD SWITCH PRESSURE [2380GM] .
(b) If the internal leakage is in the given limits: 1 Do a check of the filter elements of the CASE DRAIN FILT.ELEC.PUMP B [2084GM] , HP-FILTER B [2048GM] and LP FILTER B [2002GM] .
2 Replace the filter element as necessary AMM 29-12-43-610-001 or AMM 29-12-45-610-001 or AMM 29-12-44-610-001.
B. If the test gives:
(a) Disconnect theTEMP TRANSM SWITCH-connector plug (2381GR-A) from the TEMP TRANSM SWITCH [2381GR] and do a visual check of the connector's integrity.
1 If the connector is not in the correct condition:
1 If there is no continuity, replace the TEMP TRANSM SWITCH [2381GR] AMM 29-33-11-000-002 AMM 29-33-11-400-002.
(c) Do a check of the continuity between pin A/F and pin A/E of the TEMP TRANSM SWITCH [2381GR] ASM 293301.
1 If there is no continuity, replace the TEMP TRANSM SWITCH [2381GR] AMM 29-33-11-000-002 AMM 29-33-11-400-002.
(d) Measure the DC resistance between the pins A/G and A/K and between the pins A/E and A/F of the TEMP TRANSM SWITCH [2381GR] with an OHMMETER MODEL 260.
1 If the difference is more than 1.5 Ohm between the two measurements, replace the TEMP TRANSM SWITCH [2381GR] AMM 29-33-11-000-002 AMM 29-33-11-000-002.
(e) If the fault continues, make sure that the wiring is not connected to GND between theTEMP TRANSM SWITCH-connector plug (2381GR-A) , pin E and the SDAC-1 [1WV1] connector AB, pin 11A ASM 293301.
1 If the wiring is connected to GND, repair the wiring as necessary.
(f) If the fault continues, make sure that the wiring is not connected to GND between theTEMP TRANSM SWITCH-connector plug (2381GR-A) , pin K and the SDAC-2 [1WV2] connector AB, pin 11A ASM 293301.
1 If the wiring is connected to GND, repair the wiring as necessary.
(g) If the fault continues, do the operational test of the central warning system AMM 31-50-00-710-001.
1 If the test gives the maintenance message SDAC-1 : B HYD TEMP XMTR 2381GR:
Subtask 29-12-00-810-079-A - The message HYD B RSVR OVHT on the upper ECAM DU
- The OVHT flag on the HYD page of the lower ECAM DU.
NOTE: If the P/BSW FAULT light is not on the OVHT warning condition is only detected by the TEMP XDCRs of the RSVR TEMP sensor FIN 2381GR. It is referred to as a spurious warning from the TEMP XDRCs or wiring or System Data Acquisition Concentrators (SDACs).
(1) Do a wiring check: (a) Disconnect the
1 If the connector is not in the correct condition:
- Replace the TEMP TRANSM SWITCH [2381GR] , AMM 29-33-11-000-002 AMM 29-33-11-400-002 and replace the
TEMP TRANSM SWITCH-connector plug (2381GR-A) .
1 If there is no continuity, replace the TEMP TRANSM SWITCH [2381GR] AMM 29-33-11-000-002 AMM 29-33-11-400-002.
(c) Do a check of the continuity between pin A/F and pin A/E of the TEMP TRANSM SWITCH [2381GR] ASM 293301.
1 If there is no continuity, replace the TEMP TRANSM SWITCH [2381GR] AMM 29-33-11-000-002 AMM 29-33-11-400-002.
(d) Measure the DC resistance between the pins A/G and A/K and between the pins A/E and A/F of the TEMP TRANSM SWITCH [2381GR] with an OHMMETER MODEL 260.
1 If the difference is more than 1.5 Ohm between the two measurements, replace the TEMP TRANSM SWITCH [2381GR] AMM 29-33-11-000-002 AMM 29-33-11-000-002.
(e) If the fault continues, make sure that the wiring is not connected to GND between the
1 If the wiring is connected to GND, repair the wiring as necessary.
(f) If the fault continues, make sure that the wiring is not connected to GND between the
1 If the wiring is connected to GND, repair the wiring as necessary.
(g) If the fault continues, do the operational test of the central warning system AMM 31-50-00-710-001.
1 If the test gives the maintenance message SDAC-1 : B HYD TEMP XMTR 2381GR:
- Rreplace the SDAC-1 [1WV1] AMM 31-55-34-000-001 AMM 31-55-34-400-001.
- Replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 AMM 31-55-34-000-001.
C. If the test gives:
(a) Do a check of the continuity between pin A/A and pin A/B of the TEMP TRANSM SWITCH [2381GR] ASM 293301.
1 If there is continuity, replace the TEMP TRANSM SWITCH [2381GR] AMM 29-33-11-000-002 AMM 29-33-11-400-002
2 If there is no continuity, make sure that the wiring is not connected to GND betweenTEMP TRANSM SWITCH-connector plug (2381GR-A) , pin B and the diode block 1156VD, pin 32 ASM 293301 ASM 291201 .
a If the wiring is connected to GND, repair the wiring as necessary.
(b) If the fault continues, make sure that the wiring is not connected to GND betweenTEMP TRANSM SWITCH-connector plug (2381GR-A) , pin B and the SDAC-1 [1WV1] connector AA, pin 4E ASM 293301.
1 If the wiring is connected to GND, repair the wiring as necessary.
(c) If the fault continues, make sure that the wiring is not connected to GND betweenTEMP TRANSM SWITCH-connector plug (2381GR-A) , pin B and the SDAC-2 [1WV2] connector AA, pin 4E ASM 293301.
1 If the wiring is connected to GND, repair the wiring as necessary.
(d) If the fault continues, do the operational test of the central warning system AMM 31-50-00-710-001.
1 If the test gives the maintenance message SDAC-1 : B HYD TEMP XMTR 2381GR:
Subtask 29-12-00-710-056-A - The message HYD B RSVR OVHT on the upper ECAM DU
- The BLUE ELEC PUMP P/BSW FAULT light on panel 40VU.
NOTE: If the OVHT flag is not shown on the HYD page of the lower ECAM DU, this confirms that the OVHT warning condition is only detected by the thermal switch of the RSVR TEMP sensor FIN 2381GR. It is referred to as a spurious warning from the thermal switch or wiring or SDACs.
(1) Do a wiring check: (a) Do a check of the continuity between pin A/A and pin A/B of the TEMP TRANSM SWITCH [2381GR] ASM 293301.
1 If there is continuity, replace the TEMP TRANSM SWITCH [2381GR] AMM 29-33-11-000-002 AMM 29-33-11-400-002
2 If there is no continuity, make sure that the wiring is not connected to GND between
a If the wiring is connected to GND, repair the wiring as necessary.
(b) If the fault continues, make sure that the wiring is not connected to GND between
1 If the wiring is connected to GND, repair the wiring as necessary.
(c) If the fault continues, make sure that the wiring is not connected to GND between
1 If the wiring is connected to GND, repair the wiring as necessary.
(d) If the fault continues, do the operational test of the central warning system AMM 31-50-00-710-001.
1 If the test gives the maintenance message SDAC-1 : B HYD TEMP XMTR 2381GR:
- Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 AMM 31-55-34-400-001.
- Replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 AMM 31-55-34-400-001.
D. Do the test as given in Para. 3. B. to make sure that operation is correct (no maintenance message shown).
5. Close-upSubtask 29-12-00-860-051-A
A. Aircraft Maintenance Configuration
(1) Make sure the Blue hydraulic system is depressurized AMM 29-10-00-864-003.
(2) Make sure that the aircraft electrical circuits are de-energized AMM 24-41-00-862-002.
(1) Make sure the Blue hydraulic system is depressurized AMM 29-10-00-864-003.
(2) Make sure that the aircraft electrical circuits are de-energized AMM 24-41-00-862-002.