Fuel-Crossfeed Valve status is not available or is shown incorrectly on the ECAM FUEL page
TASK 28-23-00-810-804-A
Fuel-Crossfeed Valve status is not available or is shown incorrectly on the ECAM FUEL page
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 28-23-00-700-052-A
Subtask 28-23-00-810-053-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:40 UTC
Fuel-Crossfeed Valve status is not available or is shown incorrectly on the ECAM FUEL page
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
WARNING:
WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT: EN50020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
1. Possible Causes2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 28-23-00-810-801-A | Fuel-Crossfeed Valve Does Not Open (Close) or Opens (Closes) Slowly |
| TSM TASK 28-23-00-810-802-A | Fuel-Crossfeed Valve P/BSW-4QE, ON and/or OPEN legends do not come on |
| ESPM 2052210 | |
| ESPM 2053210 | |
| CMM 280111 | |
| AMM 28-23-00-720-001 | Operational Test of Crossfeed Valve Using Individual Motors: ... |
| ASM 282301 | |
| AMM 28-23-51-000-001 | Removal of the Crossfeed Valve Actuator |
| AMM 28-23-51-400-001 | Installation of the Crossfeed Valve Actuator |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 28-23-00-700-052-A
A. Test
(1) Do the procedure for the operational test of the crossfeed valve using individual motors AMM 28-23-00-720-001.
4. Fault Isolation(1) Do the procedure for the operational test of the crossfeed valve using individual motors AMM 28-23-00-720-001.
NOTE: During the operational test when the C/B-2QE is set to open, the OPEN legend of the P/BSW-4QE will not come on. This is because the C/B-2QE also supplies 28VDC to the related lamp control circuit in the BOARD-ANN LT TEST & INTFC (6LP).
(2) If, during the test of the crossfeed system: - the crossfeed valve (10QM) does not open and/or close, do the procedure (Ref. TSM TASK 28-23-00-810-801)
- the ON and/or the OPEN legends of the P/BSW-4QE do not come on, do the procedure (Ref. TSM TASK 28-23-00-810-802)
- the crossfeed valve status (symbol), relative to the P/BSW-4QE position (command) and the valve (see/feel indicator) position, is not shown correctly on the FUEL page, do the Para. 4.A.
Subtask 28-23-00-810-053-A
A. Procedure
(1) Do a check of the actuator-5QE as follows:
(c) With a MULTIMETER - STANDARD, do a continuity check ESPM 2052210 of the actuator internal position indication microswitches ASM 282301 as follows:
1 If the actuator see/feel indicator in step (b) was:
a In the closed position
At the actuator receptacle R1 do a check for:
At the actuator receptacle R1 do a check for:
(f) If the actuator-5QE position indication microswitches:
(1) Do a check of the actuator-5QE as follows:
NOTE: This step is necessary because although the actuator crossfeed valve 5QE see/feel indicator has moved to the open (closed) position, the internal position indication microswitch OPEN (CLOSED) contacts and/or the related wiring can be unserviceable.
(a) Disconnect the connector 5QE-A from the actuator receptacle R1. NOTE: The text reference to R1 relates to one of the actuator electrical receptacles and is etched onto the gearbox housing.
(b) Monitor the actuator-5QE see/feel indicator and make a record of its position. (c) With a MULTIMETER - STANDARD, do a continuity check ESPM 2052210 of the actuator internal position indication microswitches ASM 282301 as follows:
1 If the actuator see/feel indicator in step (b) was:
a In the closed position
At the actuator receptacle R1 do a check for:
- continuity between the pins B and E
- open circuit between the pins D and E.
At the actuator receptacle R1 do a check for:
- open circuit between the pins B and E
- continuity between the pins D and E.
NOTE: The multimeter reading for continuity should be less than 1 ohm CMM 280111.
(d) Push (in) or release (out) the P/BSW-4QE to change the actuator position. NOTE: This is done with motor 2 supplied through the connector 5QE-B that is still connected to receptacle R2.
(e) Do the step (d) again for the opposite condition. (f) If the actuator-5QE position indication microswitches:
- do not pass all the tests given in step (c), replace the ACTUATOR-FUEL CROSSFEED VALVE [5QE] AMM 28-23-51-000-001 and AMM 28-23-51-400-001
- pass all the tests given in step (c), are serviceable, do step (2).
- The connector 5QE-A, pin D and the SDAC-1, rack connector 1WV1-A, pin 13H
- The connector 5QE-A, pin D and the SDAC-2, rack connector 1WV2-A, pin 13H
- The connector 5QE-A, pin B and the SDAC-1, rack connector 1WV1-A, pin 14H
- The connector 5QE-A, pin B and the SDAC-2, rack connector 1WV2-A, pin 14H.
- Repair or replace the unserviceable wiring and connectors ESPM 2053210.
- Do the test in Para. 3.A.
- If the fault continues, do step (b).
- Replace the applicable SDAC-1 [1WV1] or SDAC-2 [1WV2] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.