Loss of the Signal of the Right Blue Elevator-Servocontrol Position-Transducer by the ELAC 1


TASK 27-93-00-810-871-A
Loss of the Signal of the Right Blue Elevator-Servocontrol Position-Transducer by the ELAC 1


1. Possible Causes
  • ELAC-1 [2CE1]
  • wiring of the POS XDCR COM (ANI 2-2) signal from the ELAC 1 (2CE1) to the first terminal block
  • SERVO CTL-R ELEVATOR, OUTBD B [34CE4]
  • SERVO CTL-R ELEVATOR, INBD Y [34CE2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-30-00-810-848-A
Elevator Damping Test Not Possible
TSM TASK 27-90-00-810-811-A
Loss of the ACS1 Signal of the ELAC1 COM Side
TSM TASK 27-90-00-810-812-A
Loss of the ACS1 Signal of the ELAC1 MON Side
TSM TASK 27-90-00-810-813-A
Loss of the ACS1 of the ELAC1 COM and MON Sides
AMM 27-34-00-710-001
Operational Test of the Elevator and Hydraulic Actuation
AMM 27-34-51-000-001
Removal of the Elevator Servo Control
AMM 27-34-51-400-001
Installation of the Elevator Servo Control
ASM 279307
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-710-008
Operational Test of the Damping Measurement (Elevator)
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-93-00-700-126-A
A. Test
   (1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
     (a) If the ground scanning gives the maintenance message:
ELAC1 OR WIRING FROM R B ELEV POS XDCR 34CE4
  • refer to Para. Fault Isolation.
     (b) If the ground scanning gives at least two maintenance messages of the two lists below:
First list:
  • ELAC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
  • ELAC1 OR WIRING FROM L B ELEV POS XDCR 34CE3
  • ELAC1 OR WIRING FROM R B ELEV POS XDCR 34CE4
    Second list:
  • ELAC1 MON OR WIRING FROM THS ACTR XDCR2 9CE
  • ELAC1 OR WIRING FROM L ELEV POS MON XDCR
  • ELAC1 OR WIRING FROM R ELEV POS MON XDCR
  • ELAC1 OR WIRING FROM L G ELEV MODE XDCR 34CE1
  • ELAC1 OR WIRING FROM R Y ELEV MODE XDCR 34CE2
       1 First case:
Combination of maintenance messages of the first list, do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-811).
       2 Second case:
Combination of maintenance messages of the second list, do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-812).
       3 Third case:
Combination of maintenance messages of the first and second lists, do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-813).
4. Fault Isolation
Subtask 27-93-00-810-118-A
A. If the test gives the maintenance message:
ELAC1 OR WIRING FROM R B ELEV POS XDCR 34CE3
   (1) If the fault continues:
  • Do a check and repair the wiring of the POS XDCR COM (ANI 2-2) signal from the ELAC 1 (2CE1) to the first terminal block ASM 279307.
   (2) If the fault continues:
     (a) Do the operational test of the elevator and hydraulic actuation AMM 27-34-00-710-001:
       1 If the travel speed of the right elevator is less than the travel speed of the left elevator:
         a Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
         b If the travel speed of the right elevator is again less than the travel speed of the left elevator, replace the SERVO CTL-R ELEVATOR, INBD Y [34CE2] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
       2 If the two elevators move with the same travel speeds, continue this procedure (para.(b)).
     (b) Do a damping test AMM 27-96-00-710-008:
       1 If the ELEV TEST NOT POSSIBLE message is shown, do the trouble shooting procedure (Ref. TSM TASK 27-30-00-810-848).
       2 If the R ELEV TEST OK message is shown and the damping factor of one elevator servocontrol is higher than 1:
       3 If the R ELEV TEST OK message is shown and the damping factors of two elevator servocontrols are higher than 1:
         a Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
         b If the R ELEV TEST OK message is shown and the damping factors of two elevator servocontrols are again higher than 1: replace the SERVO CTL-R ELEVATOR, INBD Y [34CE2] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
Subtask 27-93-00-700-127-A
B. Do the tests given in Para. 3.