Elevator Damping Test Not Possible
TASK 27-30-00-810-848-A
Elevator Damping Test Not Possible
A. Referenced Information
3. Fault Confirmation
Subtask 27-30-00-710-050-A
Subtask 27-30-00-810-095-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:35 UTC
Elevator Damping Test Not Possible
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
1. Possible Causes- SERVO CTL-L ELEVATOR, OUTBD B [34CE3]
- SERVO CTL-L ELEVATOR, INBD G [34CE1]
- SERVO CTL-R ELEVATOR, OUTBD B [34CE4]
- SERVO CTL-R ELEVATOR, INBD Y [34CE2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-30-00-810-851-A | Elevator Damping Test Not Possible (Decoding) |
| AMM 27-34-51-000-001 | Removal of the Elevator Servo Control |
| AMM 27-34-51-400-001 | Installation of the Elevator Servo Control |
| AMM 27-96-00-710-008 | Operational Test of the Damping Measurement (Elevator) |
Subtask 27-30-00-710-050-A
A. Not Applicable
4. Fault IsolationSubtask 27-30-00-810-095-A
A. If the TEST NOT POSSIBLE message is shown with the normal engagement code (03FF):
(a) Do an elevator operational test as follows:
(a) For the test of the left elevator:
(a) For the test of the left elevator:
Subtask 27-30-00-810-100-A - the right (left) elevator damping test has of 3 sequences as follows:
(a) Do an elevator operational test as follows:
- make sure that the Green, Blue and Yellow hydraulic systems are pressurized
- make sure that the SEC1 is engaged (the ELAC1 is disengaged)
- disengage the SEC2 (the ELAC2 is disengaged).
- on the lower ECAM DU, the two elevator indexes move at the same time with the same travel speed.
- do the action in Para. (3)(a)1_
- do the action in Para. (3)(b)1_
- make sure that the Green, Blue and Yellow hydraulic systems are pressurized
- make sure that the SEC2 is engaged (the ELAC2 is disengaged)
- disengage the SEC1 (the ELAC1 is disengaged).
- on the lower ECAM DU, the two elevator indexes move at the same time with the same travel speed.
- do the action in Para. (2)(a)1_
- do the action in Para. (2)(b)1_
(a) For the test of the left elevator:
- replace the SERVO CTL-L ELEVATOR, OUTBD B [34CE3] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
- replace the SERVO CTL-L ELEVATOR, INBD G [34CE1] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
- replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
- replace the SERVO CTL-R ELEVATOR, INBD Y [34CE2] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
(a) For the test of the left elevator:
- replace the SERVO CTL-L ELEVATOR, INBD G [34CE1] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
- replace the SERVO CTL-L ELEVATOR, OUTBD B [34CE3] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
- replace the SERVO CTL-R ELEVATOR, INBD Y [34CE2] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
- replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 AMM 27-34-51-400-001.
B. If the TEST NOT POSSIBLE message is shown with an other code (different from 03FF):
Subtask 27-30-00-710-051-A - do the trouble shooting procedure (Ref. TSM TASK 27-30-00-810-851).
Elevator Damping Test Sequences