Elevator Damping Test Not Possible (Decoding)
TASK 27-30-00-810-851-A
Elevator Damping Test Not Possible (Decoding)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-30-00-710-054-A
Subtask 27-30-00-810-099-A
[Rev.8 from Aug 2018]
2026.04.04 04:39:12 UTC
Elevator Damping Test Not Possible (Decoding)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-30-00-810-848-A | Elevator Damping Test Not Possible |
| AMM 27-96-00-710-008 | Operational Test of the Damping Measurement (Elevator) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-30-00-710-054-A
A. Not Applicable
4. Fault IsolationSubtask 27-30-00-810-099-A
A. If the ELEV TEST NOT POSSIBLE message and BITE code 03FF are shown on the MCDU :
Subtask 27-30-00-810-102-A - do the trouble shooting procedure (Ref. TSM TASK 27-30-00-810-848).
B. If the ELEV TEST NOT POSSIBLE message and BITE code other than 03FF are shown on the MCDU :
(1) Do the decoding procedure.
(1) Do the decoding procedure.
NOTE: The decoding procedure will give you the cause of the damping test failure and will help you to identify a failure message during the next step (Ground Scanning).
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001. - Identify the failure message related to the cause you found during the decoding procedure, then
- Do the associated trouble shooting procedure.
NOTE: As example, for the fault code 01FF by SEC 1, the state of R ELEV S1M AVAIL is 0 instead of 1. This signifies that SEC 1 MON (S1M) has detected a failure on the right elevator servocontrol (R ELEV). So it is necessary to search an elevator servo fault message detected by SEC 1 in the BITE test of the EFCS (Ground Scanning).
(3) Do the operational test of the damping measurement (elevator) AMM 27-96-00-710-008.
Decoding Table of the Elevator Damping Test Not Possible