Loss of the ACS1 Signal of the ELAC1 COM Side
TASK 27-90-00-810-811-A
Loss of the ACS1 Signal of the ELAC1 COM Side
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-90-00-740-069-A 4. Fault Isolation
Subtask 27-90-00-810-060-A
[Rev.8 from Aug 2018]
2026.04.04 04:39:16 UTC
Loss of the ACS1 Signal of the ELAC1 COM Side
1. Possible Causes
- ELAC-1 [2CE1]
- SEC-1 [1CE1]
- wiring of the ACS1 SPLY signal from the ELAC1 COM side to the MON side
- wiring of the ACS1 SPLY COM signal from the ELAC1 MON side to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-801-A | Failure of an Alternating Current Supply (ACS) |
| ASM 279307 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-90-00-740-069-A 4. Fault Isolation
Subtask 27-90-00-810-060-A
A. If the ground scanning gives at least two maintenance messages of the list below:
ELAC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
ELAC1 OR WIRING FROM L B ELEV POS XDCR 34CE3
ELAC1 OR WIRING FROM R B ELEV POS XDCR 34CE4
(1) Remove the ELAC1 AMM 27-93-34-000-001 and the SEC1 AMM 27-94-34-000-001.
(2) At the ELAC1 receptacle, do a check of the resistance between the pin AD/6B and the pin AD/6C ASM 279307:
(a) If the resistance is less than 10 Ohms:
1 Do this procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
3 Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(b) If the resistance is more than 10 Ohms:
a Replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
b Install the SEC1 AMM 27-94-34-400-001.
c If the fault continues:
Subtask 27-90-00-740-070-A ELAC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
ELAC1 OR WIRING FROM L B ELEV POS XDCR 34CE3
ELAC1 OR WIRING FROM R B ELEV POS XDCR 34CE4
(1) Remove the ELAC1 AMM 27-93-34-000-001 and the SEC1 AMM 27-94-34-000-001.
(2) At the ELAC1 receptacle, do a check of the resistance between the pin AD/6B and the pin AD/6C ASM 279307:
(a) If the resistance is less than 10 Ohms:
1 Do this procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
3 Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(b) If the resistance is more than 10 Ohms:
- do a check of the wiring of the ACS1 SPLY signal from the ELAC1 COM side to the MON side ASM 279307:
. pins AA/13A and AA/13B to pins AA/8K and AA/8G of the ELAC1 COM side
. pins AA/8H and AA/8J of the ELAC1 COM side to pins AD/6A and AD/6D of the ELAC1 MON side.
- repair it
- install the ELAC1 AMM 27-93-34-400-001 and the SEC1 AMM 27-94-34-400-001.
- replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
a Replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
b Install the SEC1 AMM 27-94-34-400-001.
c If the fault continues:
- do a check and repair the wiring of the ACS1 SPLY COM signal from the ELAC1 MON side to the first terminal block , pins AD/6B and AD/6C ASM 279307.
- if the wiring is correct, do the failure of an alternating current supply (ACS) procedure (Ref. TSM TASK 27-90-00-810-801).
B. Do the test given in Para. 3.