Failure of an Alternating Current Supply (ACS)
TASK 27-90-00-810-801-A
Failure of an Alternating Current Supply (ACS)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-90-00-700-050-A
Subtask 27-90-00-810-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:51 UTC
Failure of an Alternating Current Supply (ACS)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
Subtask 27-90-00-700-050-A
A. Not applicable, refer to the procedure that you did before.
4. Fault IsolationSubtask 27-90-00-810-050-A
A. Trouble shooting procedure for an ACS short circuit.
Failure that the computer(s) which receives the ANI signal from the transducers (A, B, C) senses. This failure can be:
(2) Do a check of the resistance and insulation of the LVDT/RVDT of the unit A.
(a) If the check is correct:
(4) Do a check of the resistance and insulation of the LVDT/RVDT of the unit A.
(a) If the check is correct:
(6) Do a check of the resistance and insulation of the LVDT/RVDT of the unit C.
(a) If the check is correct:
Failure that the computer(s) which receives the ANI signal from the transducers (A, B, C) senses. This failure can be:
- a short circuit in the winding of one of the transducers
- or a short circuit in the wiring (ACS).
- in the computer which supplies the transducers (A, B, C)
- or in the wiring (discontinuity).
NOTE: The computer(s) which supplies the transducers has been removed.
(1) At the unit A, disconnect the electrical connector related to the ACS. (2) Do a check of the resistance and insulation of the LVDT/RVDT of the unit A.
(a) If the check is correct:
- connect the electrical connector to the unit A
- continue the trouble shooting.
- replace the unit A or the LVDT/RVDT
- connect the electrical connector to the unit A
- refer to the procedure that you did before.
(4) Do a check of the resistance and insulation of the LVDT/RVDT of the unit A.
(a) If the check is correct:
- connect the electrical connector to the unit B
- continue the trouble shooting.
- replace the unit B or the LVDT/RVDT
- connect the electrical connector to the unit B
- refer to the procedure that you did before.
(6) Do a check of the resistance and insulation of the LVDT/RVDT of the unit C.
(a) If the check is correct:
- connect the electrical connector to the unit C
- continue, the trouble shooting.
- replace the unit C or the LVDT/RVDT
- connect the electrical connector to the unit C
- refer to the procedure that you did before.
ALTERNATING CURRENT SUPPLY (ACS)