W DOC AIRBUS | TSM A320F

Loss of the HF 1 System


TASK 23-11-00-810-810-A
Loss of the HF 1 System


1. Possible Causes
  • COUPLER-HF, 1 [4RE1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 23-11-00-810-801-A
Failure of the HF 1 Transceiver
TSM TASK 23-11-00-810-803-A
Loss of the HF 1 Communication
AMM 23-11-00-740-001
BITE Test of the HF System
AMM 23-11-36-000-001
Removal of the HF Antenna Coupler
AMM 23-11-36-400-001
Installation of the HF Antenna Coupler
3. Fault Confirmation
Subtask 23-11-00-740-064-A
A. Test
   (1) Do the BITE test of the HF system AMM 23-11-00-740-001.
NOTE: Do this test for the HF 1 only.
4. Fault Isolation
Subtask 23-11-00-810-063-A ** ON A/C NOT FOR ALL
A. If the test gives this maintenance message:
   (1) HF 1 TRANSCEIVER:
   (2) CHECK HF 1 ANTENNA CIRCUIT:
Subtask 23-11-00-810-063-E ** ON A/C NOT FOR ALL
A. If the test gives this maintenance message:
   (1) HF1 (3RE1):
   (2) HF1 (3RE1) /COAX:
Subtask 23-11-00-810-064-A
B. If the test gives no maintenance message:
[Rev.8 from Aug 2018] 2026.04.04 04:25:35 UTC