Failure of the HF 1 Transceiver


TASK 23-11-00-810-801-A
Failure of the HF 1 Transceiver


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-11-00-200-001
Check of the Electrical Bonding of the HF System
AMM 23-11-00-740-001
BITE Test of the HF System
ASM 231101
AMM 23-11-33-000-001
Removal of the HF Transceiver
AMM 23-11-33-400-001
Installation of the HF Transceiver
3. Fault Confirmation
Subtask 23-11-00-740-050-A
A. Test
Do the BITE test of the HF system AMM 23-11-00-740-001.
NOTE: Do this test for the HF 1 only.
4. Fault Isolation
Subtask 23-11-00-865-055-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM HF11RE1HA14
Subtask 23-11-00-810-050-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message HF 1 TRANSCEIVER:
  • Do a check of the circuit breaker (1RE1) status.
   (1) If the circuit breaker is closed:
  • Do a check for 115VAC at pins AC/4, 5, 6 of the HF 1 transceiver (3RE1) ASM 231101.
     (a) If there is 115VAC:
     (b) If there is no 115VAC:
  • Do a check for a ground signal at pin AC/8 of the HF 1 transceiver (3RE1) ASM 231101.
       1 If there is no ground signal:
  • Repair the wiring between the HF 1 transceiver (3RE1) pin AC/8 and the ground terminal ASM 231101.
       2 If there is a ground signal:
  • Do a check of the wiring from the circuit breaker (1RE1) to the HF 1 transceiver (3RE1) pins AC/4, 5, 6 ASM 231101.
         a If there is no continuity:
  • Repair the above wiring.
         b If there is continuity:
  • Replace the circuit breaker (1RE1).
   (2) If the circuit breaker is open:
  • Close it.
     (a) If it opens again:
       1 If the fault continues:
  • Do a check for a short to ground at the wiring between the HF 1 transceiver (3RE1) pins AC/4, 5, 6 and the circuit breaker (1RE1) ASM 231101.
         a If there is a short to ground:
  • Repair the related wiring.
         b If there is no short to ground:
  • Replace the [1RE1] .
     (b) If the circuit breaker stays closed and the fault continues:
   (3) If the fault continues:
Subtask 23-11-00-810-050-C ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message HF1 (3RE1):
  • Do a check of the circuit breaker (1RE1) status.
   (1) If the circuit breaker is closed:
  • Do a check for 115VAC at pins AC/4, 5, 6 of the HF 1 transceiver (3RE1) ASM 231101.
     (a) If there is 115VAC:
     (b) If there is no 115VAC:
  • Do a check for a ground signal at pin AC/8 of the HF 1 transceiver (3RE1) ASM 231101.
       1 If there is no ground signal:
  • Repair the wiring between the HF 1 transceiver (3RE1) pin AC/8 and the ground terminal ASM 231101.
       2 If there is a ground signal:
  • Do a check of the wiring from the circuit breaker (1RE1) to the HF 1 transceiver (3RE1) pins AC/4, 5, 6 ASM 231101.
         a If there is no continuity:
  • Repair the above wiring.
         b If there is continuity:
  • Replace the circuit breaker (1RE1).
   (2) If the circuit breaker is open:
  • Close it.
     (a) If it opens again:
       1 If the fault continues:
  • Do a check for a short to ground at the wiring (between the HF 1 transceiver (3RE1) pins AC/4, 5, 6 and the circuit breaker (1RE1)) ASM 231101.
         a If there is a short to ground:
  • Repair the related wiring.
         b If there is no short to ground:
  • Replace the C/B-COM HF1 [1RE1] .
     (b) If the circuit breaker stays closed and the fault continues:
   (3) If the fault continues:
Subtask 23-11-00-740-051-A
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:38:57 UTC