80-11 (PW11) - ENGINE STARTING
- PB.201 CONF:[21] ENGINE STARTING - FAULT ISOLATION PROCEDURES
-
80-11-00-810-821-A
[PW11]
[8]
Starter Speed (NS) in Signal Failure Channel A -
80-11-00-810-822-A
[PW11]
[8]
Starter Speed (NS) in Signal Failure Channel B -
80-11-00-810-823-A
[PW11]
[8]
Starter Speed (NS) in Disagreement Failure -
80-11-00-810-824-A
[PW11]
[8]
Starter Clutch Mechanical Failure Detected -
80-11-00-810-825-A
[PW11]
[8]
SAV cannot be Powered by EEC, Except in Case of Power Fault Channel A -
80-11-00-810-826-A
[PW11]
[8]
SAV cannot be Powered by EEC, Except in Case of Power Fault Channel B -
80-11-00-810-827-A
[PW11]
[8]
SAV Failed Closed -
80-11-00-810-828-A
[PW11]
[8]
SAV Failed Open -
80-11-00-810-852-A
[PW11]
[8]
SAV cannot be powered by EEC
-
80-11-00-810-821-A
[PW11]
[8]