W DOC AIRBUS | TSM A320F

SAV cannot be powered by EEC


TASK 80-11-00-810-852-A
SAV cannot be powered by EEC


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 80-11-00-810-825-A
SAV cannot be Powered by EEC, Except in Case of Power Fault Channel A
TSM TASK 80-11-00-810-826-A
SAV cannot be Powered by EEC, Except in Case of Power Fault Channel B
3. Fault Confirmation
Subtask 80-11-00-710-117-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 80-11-00-810-150-A ** ON A/C NOT FOR ALL
A. Do the two task as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 80-11-00-810-825).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 80-11-00-810-826).
5. Close-up
Subtask 80-11-00-860-075-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:38:43 UTC