Check of the Oil System for Oil Quantity [CFMB]
TASK 79-31-00-040-042-A
Check of the Oil System for Oil Quantity
1. Reason for the Job
MMEL 79-07-03A
OIL QUANTITY INDICATION ON THE ENGINE SD PAGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 79-31-00-861-050-A ** ON A/C NOT FOR ALL Subtask 79-31-00-941-050-A ** ON A/C NOT FOR ALL
Subtask 79-31-00-210-050-A ** ON A/C NOT FOR ALL
Subtask 79-31-00-941-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:39:29 UTC
Check of the Oil System for Oil Quantity
1. Reason for the Job
MMEL 79-07-03A
OIL QUANTITY INDICATION ON THE ENGINE SD PAGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-13-79-610-002-A | Check oil level and replenish Check Pop Out Indicator of EMCD (Electrical Master Chip Detector) |
| TASK 12-13-79-610-002-A-01 | Check oil level and replenish (Pressure Filling) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 79-31-00-861-050-A ** ON A/C NOT FOR ALL Subtask 79-31-00-941-050-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
4. Procedure(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 79-31-00-210-050-A ** ON A/C NOT FOR ALL
A. Do a Check of the Oil Quantity
(1) Do a check of the oil level in the tank and fill it to the correct level if necessary (Ref. AMM TASK 12-13-79-610-002).
5. Close-up(1) Do a check of the oil level in the tank and fill it to the correct level if necessary (Ref. AMM TASK 12-13-79-610-002).
NOTE: The necessary quantity is the minimum quantity plus the consumption estimate for the flight.
Subtask 79-31-00-941-051-A ** ON A/C NOT FOR ALL
A. Indicating system
(1) Put a WARNING NOTICE(S) in the cockpit to tell persons that the oil quantity indication does not operate.
(2) Make an entry in the log book to record the check.
Subtask 79-31-00-865-050-A ** ON A/C NOT FOR ALL (1) Put a WARNING NOTICE(S) in the cockpit to tell persons that the oil quantity indication does not operate.
(2) Make an entry in the log book to record the check.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 79-31-00-862-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 121VU | ENGINE/ENG1/OIL/QTY | 1EN1 | N39 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 121VU | ENGINE/ENG2/OIL/QTY | 1EN2 | N41 |