W DOC AIRBUS | AMM A320F

Check of the Oil System for Oil Quantity [CFMB]


TASK 79-31-00-040-042-A
Check of the Oil System for Oil Quantity


1. Reason for the Job
MMEL 79-07-03A
OIL QUANTITY INDICATION ON THE ENGINE SD PAGE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 12-13-79-610-002-A
Check oil level and replenish Check Pop Out Indicator of EMCD (Electrical Master Chip Detector)
TASK 12-13-79-610-002-A-01
Check oil level and replenish (Pressure Filling)
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 79-31-00-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
Subtask 79-31-00-941-050-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
4. Procedure
Subtask 79-31-00-210-050-A ** ON A/C NOT FOR ALL
A. Do a Check of the Oil Quantity
   (1) Do a check of the oil level in the tank and fill it to the correct level if necessary (Ref. AMM TASK 12-13-79-610-002).
NOTE: The necessary quantity is the minimum quantity plus the consumption estimate for the flight.
5. Close-up
Subtask 79-31-00-941-051-A ** ON A/C NOT FOR ALL
A. Indicating system
   (1) Put a WARNING NOTICE(S) in the cockpit to tell persons that the oil quantity indication does not operate.
   (2) Make an entry in the log book to record the check.
Subtask 79-31-00-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
121VUENGINE/ENG1/OIL/QTY1EN1N39
FOR FIN: 1000EM2 (ENGINE2)
121VUENGINE/ENG2/OIL/QTY1EN2N41
Subtask 79-31-00-862-050-A ** ON A/C NOT FOR ALL
C. De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001).