W DOC AIRBUS | AMM A320F

General Visual Inspection of "C" Duct Hinge Fittings [CFMB]


TASK 78-32-00-210-045-B
General Visual Inspection of "C" Duct Hinge Fittings


ZONE: 400
1. Reason for the Job
Refer to the MPD TASK: 783200-01
GENERAL VISUAL INSPECTION OF "C" DUCT HINGE FITTINGS
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 45 and 35 lbf.in (0.51 and 0.40 m.daN ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-32-11-000-002-A
Removal of the Left or Right Half Door of Thrust Reverser
TASK 78-32-11-400-002-A
Installation of the Left or Right Half Door of Thrust Reverser
3. Job Set-up
Subtask 78-32-00-941-064-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-32-00-010-082-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR.
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-32-00-040-063-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 78-32-00-010-083-A ** ON A/C NOT FOR ALL
D. Remove the hinge access panel as follows:
   (1) Remove the 12 screws (10) from the access panel (5).
   (2) Remove the panel (5).
4. Procedure
Subtask 78-32-00-210-063-A ** ON A/C NOT FOR ALL
A. General Visual Inspection of the Thrust Reverser Door Hinges and Attachment Hardware
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Crack
None allowed
If cracks are found, replace the thrust reverser half door (Ref. AMM TASK 78-32-11-000-002) and (Ref. AMM TASK 78-32-11-400-002).
2.Dent
None allowed
If dents are found, replace the thrust reverser half door (Ref. AMM TASK 78-32-11-000-002) and (Ref. AMM TASK 78-32-11-400-002).
3.Corrosion
None allowed
If corrosion is found on the thrust reverser hinge structure, replace the thrust reverser half door (Ref. AMM TASK 78-32-11-000-002) and (Ref. AMM TASK 78-32-11-400-002).
If corrosion is found on the hinge pin(s) or hardware, replace the damaged bolt(s) or hardware (Ref. AMM TASK 78-32-11-000-002) and (Ref. AMM TASK 78-32-11-400-002).
4.Loose hardware
None allowed
Tighten the hardware (Ref. AMM TASK 78-32-11-400-002).
5.Missing hardware
None allowed
Replace the missing hardware (Ref. AMM TASK 78-32-11-400-002).
6.Worn bushing
None allowed
Replace the bushing. Refer to CFM56-5B Nacelle SRM 54-30-00 (Cage Code 51563), Repair No. 17.
5. Close-up
Subtask 78-32-00-410-080-A ** ON A/C NOT FOR ALL
A. Install the hinge access panel as follows:
   (1) Install the hinge access panel (5) and attach with screws (10).
   (2) TORQUE the screws (10) to between 45 and 35 lbf.in (0.51 and 0.40 m.daN ) T.
Subtask 78-32-00-440-062-A ** ON A/C NOT FOR ALL Subtask 78-32-00-410-081-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:25:40 UTC