W DOC AIRBUS | AMM A320F

General Visual Inspection of the Exhaust System Fire Seals [IAE]


TASK 78-10-00-200-010-A
General Visual Inspection of the Exhaust System Fire Seals


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 781000-I1
GENERAL VISUAL INSPECTION OF THE EXHAUST SYSTEM FIRE SEALS
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.V01-031)
Acetone, Technical grade
(Material No.V01-124)
Isopropyl Alcohol, Technical grade
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
3. Job Set-up
Subtask 78-10-00-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-10-00-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowls doors (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position.
Subtask 78-10-00-040-050-A ** ON A/C NOT FOR ALL
C. Deactivate the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012).
Subtask 78-10-00-010-051-A ** ON A/C NOT FOR ALL
D. Open the Thrust Reverser Halves (Ref. AMM TASK 78-32-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-10-00-110-050-A ** ON A/C NOT FOR ALL
E. Clean Components
   (1) Clean the mixed exhaust system components which follow with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with solvent cleaner Desoclean 45 PRC Desoto International Telephone Toll Free (800) AREOMIX (Material No. 020X413) or V01-124Isopropyl Alcohol, Technical grade or V01-031Acetone, Technical grade.
     (a) Fire seal and pressure seals.
4. Procedure
Subtask 78-10-00-210-050-A ** ON A/C NOT FOR ALL
A. Examine the Mixed Exhaust System
F Mixed Exhaust System ** ON A/C NOT FOR ALL
   (1) Examine the seals:
     (a) Examine the mixed-exhaust system fire-seals and pressure seals for cracks, wear or other obvious damage. If you find damage, replace the damaged part by a new one or contact Airbus for disposition.
     (b) Make sure that the fire seals and pressure seals are attached correctly and that they are not loose.
5. Close-up
Subtask 78-10-00-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-10-00-440-050-A ** ON A/C NOT FOR ALL
B. Activate the Thrust Reverser Hydraulic Control Unit (Ref. AMM TASK 78-30-00-440-012).
Subtask 78-10-00-410-051-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowls doors (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:26:55 UTC