Removal of the Variable Bleed Valve position Sensor [CFMB]
TASK 75-31-70-000-002-A
Removal of the Variable Bleed Valve position Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 75-31-70-941-051-A ** ON A/C NOT FOR ALL
Subtask 75-31-70-820-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 13:08:33 UTC
Removal of the Variable Bleed Valve position Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 75-31-20-820-001-A | Set the Variable Bleed Valve Assembly to the Closed position |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
Subtask 75-31-70-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 75-31-70-010-053-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 75-31-70-040-052-A ** ON A/C NOT FOR ALL Subtask 75-31-70-010-054-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
D. Open the thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 75-31-70-820-051-A ** ON A/C NOT FOR ALL
A. Make sure the two reference marks are in line. If not, set the VBV system to closed position (Ref. AMM TASK 75-31-20-820-001).
Subtask 75-31-70-020-051-A ** ON A/C NOT FOR ALL B. Disconnect the 2 electrical cables
PRE SB CFM 75-006
POST SB CFM 75-006
END OF SB CFM 75-006
(1) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(2) Remove the nut (30) and the pin (60) which secures the feedback rod clevis (20) to VBV sensor arm.
PRE SB CFM 75-006
(3) Remove the 3 bolts (50) which secure the VBV sensor (40) to stop mechanism and remove the sensor.
POST SB CFM 75-006
(4) Remove the 3 bolts (50) and (55) which secure the VBV sensor (40) to stop mechanism and remove the sensor.
END OF SB CFM 75-006
PRE SB CFM 75-006
POST SB CFM 75-006
END OF SB CFM 75-006
(1) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(2) Remove the nut (30) and the pin (60) which secures the feedback rod clevis (20) to VBV sensor arm.
NOTE: Do not loosen nut (10) securing clevis (20) to feedback rod.
PRE SB CFM 75-006
(3) Remove the 3 bolts (50) which secure the VBV sensor (40) to stop mechanism and remove the sensor.
POST SB CFM 75-006
(4) Remove the 3 bolts (50) and (55) which secure the VBV sensor (40) to stop mechanism and remove the sensor.
END OF SB CFM 75-006
Variable Bleed Valve (VBV) Feedback Sensor - PRE SB CFM 75-006