W DOC AIRBUS | AMM A320F

Set the Variable Bleed Valve Assembly to the Closed position [CFMB]


TASK 75-31-20-820-001-A
Set the Variable Bleed Valve Assembly to the Closed position


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
856A2501
1
WRENCH-VBV MANUAL CONTROL
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 72-23-00-000-027-A
Removal of the Fan Duct Panels
TASK 72-23-00-400-027-A
Installation of the Fan Duct Panels
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-B
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 75-31-20-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 75-31-20-010-058-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 75-31-20-040-051-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 75-31-20-010-059-A ** ON A/C NOT FOR ALL
D. Open the thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure
Subtask 75-31-20-010-060-A ** ON A/C NOT FOR ALL
A. Remove the fan duct panel between struts No.3 and No.4 (panel at the 2:30 o'clock position) or the fan duct panel between struts No.4 and No.5 (panel at the 3:30 o'clock position) (Ref. AMM TASK 72-23-00-000-027).
Subtask 75-31-20-820-051-A ** ON A/C NOT FOR ALL
B. Set the VBV doors to the Closed position. Use 856A2501 WRENCH-VBV MANUAL CONTROL (856A2501G01) at 2:30 or at 3:30 o'clock to do this.
Subtask 75-31-20-410-058-A ** ON A/C NOT FOR ALL
C. Install the fan duct panels at the 2:30 or 3:30 o'clock (Ref. AMM TASK 72-23-00-400-027).
5. Close-up
Subtask 75-31-20-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close thrust reverser cowl doors: (Ref. AMM TASK 78-36-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 75-31-20-440-051-A ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 75-31-20-410-060-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 12:59:33 UTC