Installation of the Ignition Exciter Cooling Tubes [IAE]
TASK 75-27-49-400-010-A
Installation of the Ignition Exciter Cooling Tubes
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 75-27-49-860-050-A ** ON A/C NOT FOR ALL
Subtask 75-27-49-420-050-A ** ON A/C NOT FOR ALL
Subtask 75-27-49-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:11:43 UTC
Installation of the Ignition Exciter Cooling Tubes
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
Subtask 75-27-49-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
Subtask 75-27-49-010-052-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-010)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Make sure that the right thrust reverser half is open (Ref. AMM TASK 78-32-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
452AR
(b) FOR [1000EM2] (ENGINE-2)
462AR
Subtask 75-27-49-040-051-A ** ON A/C NOT FOR ALL (1) Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-010)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Make sure that the right thrust reverser half is open (Ref. AMM TASK 78-32-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
452AR
(b) FOR [1000EM2] (ENGINE-2)
462AR
C. Make sure that the thrust reverser Hydraulic Control Unit (HCU) is deactivated: (Ref. AMM TASK 78-30-00-040-012)
4. ProcedureSubtask 75-27-49-420-050-A ** ON A/C NOT FOR ALL
A. Install the air inlet hoses:
(1) Remove all caps from the openings.
(2) Install the air inlet hose (4)
(a) Connect the air inlet hose (4) to the connections of the air inlet lower fitting and the ignition lower cooler box.
(b) Put the hose clamps (6) and (5) in to position.
(c) Tighten the hose clamp screws by hand.
(3) Install the air inlet hose (2)
(a) Connect the air inlet hose (2) to the connections of the air inlet upper fitting and the ignition upper cooler box.
(b) Put the hose clamps (1) and (3) in to position.
(c) Tighten the hose clamp screws by hand.
5. Close-up(1) Remove all caps from the openings.
(2) Install the air inlet hose (4)
(a) Connect the air inlet hose (4) to the connections of the air inlet lower fitting and the ignition lower cooler box.
(b) Put the hose clamps (6) and (5) in to position.
(c) Tighten the hose clamp screws by hand.
(3) Install the air inlet hose (2)
(a) Connect the air inlet hose (2) to the connections of the air inlet upper fitting and the ignition upper cooler box.
(b) Put the hose clamps (1) and (3) in to position.
(c) Tighten the hose clamp screws by hand.
Subtask 75-27-49-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the right thrust reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
452AR
(b) FOR [1000EM2] (ENGINE-2)
462AR
Subtask 75-27-49-440-050-A ** ON A/C NOT FOR ALL Subtask 75-27-49-410-051-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the right thrust reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
452AR
(b) FOR [1000EM2] (ENGINE-2)
462AR
Ignition Exciter Cooling Tubes