Removal of the Active Clearance Control (ACC) Heat Shield Blankets [PW11]
TASK 75-24-41-000-802-A
Removal of the Active Clearance Control (ACC) Heat Shield Blankets
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 75-24-41-941-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:12:59 UTC
Removal of the Active Clearance Control (ACC) Heat Shield Blankets
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AND THE ADJACENT COMPONENTS AFTER ENGINE SHUTDOWN. THE ENGINE, THE ENGINE OIL AND THE ADJACENT COMPONENTS CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
Subtask 75-24-41-941-057-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
Subtask 75-24-41-010-058-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 75-24-41-040-054-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
C. Deactivation of the Thrust Reverser for Maintenance
Subtask 75-24-41-010-059-A ** ON A/C NOT FOR ALL WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805). D. Get Access
(1) Open the right thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
4. Procedure(1) Open the right thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
CAUTION:
DO NOT LET THE THERMAL INSULATION BLANKETS BECOME WET. FLUIDS CAN GO INTO THE VENT HOLES OF THE BLANKETS AND MAKE THE INSULATION UNSATISFACTORY.
CAUTION:
BE CAREFUL WHEN YOU MOVE THE THERMAL INSULATION BLANKETS. IF YOU DO NOT HOLD THE BLANKETS CORRECTLY, THEY CAN FOLD BECAUSE OF THEIR OWN WEIGHT.
DO NOT STEP ON OR PUT OBJECTS ON THE BLANKETS.
DO NOT PUT THE BLANKETS ON SURFACES THAT CAN CAUSE DAMAGE.
HOLD THE BLANKETS ON THEIR THICKEST PARTS.
IF YOU DO NOT OBEY THESE INSTRUCTIONS, DAMAGE TO THE BLANKETS CAN OCCUR.
Subtask 75-24-41-020-052-A ** ON A/C NOT FOR ALL A. Removal of the ACC Heat Shield Blankets
(1) Remove the four retainers (1) that attach the upper ACC shield blanket (3) and the lower ACC shield blanket (2) to the ACC duct.
(2) Remove the lower ACC shield blanket (2) and the upper ACC shield blanket (3) from the ACC duct.
(1) Remove the four retainers (1) that attach the upper ACC shield blanket (3) and the lower ACC shield blanket (2) to the ACC duct.
(2) Remove the lower ACC shield blanket (2) and the upper ACC shield blanket (3) from the ACC duct.
Active Clearance Control (ACC) Heat Shield Blankets