W DOC AIRBUS | AMM A320F

General Visual Inspection of the Turbine Cooling Air Tubes for Condition and Security [IAE]


TASK 75-23-00-200-010-A
General Visual Inspection of the Turbine Cooling Air Tubes for Condition and Security


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
3. Job Set-up
Subtask 75-23-00-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 75-23-00-010-052-A ** ON A/C NOT FOR ALL
B. Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 75-23-00-040-050-A ** ON A/C NOT FOR ALL
C. Deactivate the thrust reverser.
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Deactivate the thrust reverser hydraulic control unit (HCU) (Ref. AMM TASK 78-30-00-040-012).
Subtask 75-23-00-010-050-A ** ON A/C NOT FOR ALL
D. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
4. Procedure
Subtask 75-23-00-210-050-A ** ON A/C NOT FOR ALL
A. Examine the tubes:
   (1) Visually examine the PS3 cooling air tubes and the TCA tubes.
     (a) Reject the tubes if they have cracks.
5. Close-up
Subtask 75-23-00-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 75-23-00-440-050-A ** ON A/C NOT FOR ALL
B. Activate the thrust reverser HCU (Ref. AMM TASK 78-30-00-440-012).
Subtask 75-23-00-410-050-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:11:14 UTC