Removal of the High Pressure Turbine (HPT) Active Clearance Control (ACC) Wye Duct [CFML]


TASK 75-21-10-000-803-A
Removal of the High Pressure Turbine (HPT) Active Clearance Control (ACC) Wye Duct


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
CAP - PROTECTION
No specific
AR
COVER - PROTECTION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR, 451AL
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR, 461AL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
TASK 78-30-00-040-809-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-36-00-010-806-A
Opening of the Thrust Reverser Cowl Doors
3. Job Set-up
Subtask 75-21-10-941-054-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put WARNING NOTICE(S) in position to tell persons not to operate:
  • The ENG/MODE selector switch, and
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 75-21-10-010-061-A
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (2) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 75-21-10-040-056-A
C. Deactivation of the Thrust Reverser System for Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-809).
Subtask 75-21-10-010-062-A
D. Get Access
   (1) Open the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-806):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL
4. Procedure
Subtask 75-21-10-020-053-A
A. Removal of the HPT ACC Wye Duct
   (1) Remove the HPT ACC wye duct (1) as follows:
     (a) Remove the hose clamp (5) that attaches the HPT ACC wye duct (1) to the HPTACC valve (2).
     (b) Remove the hose clamp (4) that attaches the HPT ACC wye duct (1) to the LPTACC valve (3).
     (c) Remove the hose clamp (6) that attaches the HPT ACC wye duct (1) and the bracket (8) to the ACC inlet duct (7).
     (d) Remove the HPT ACC wye duct (1) from the engine.
   (2) Install the COVER - PROTECTION and CAP - PROTECTION on all the openings, tubes, hoses and disconnected connectors.