W DOC AIRBUS | AMM A320F

Removal of Ignition Exciter 1 [CFML]


TASK 74-11-05-000-801-A
Removal of Ignition Exciter 1


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: BEFORE YOU START WORK ON THE IGNITION SYSTEM, MAKE SURE THAT THE IGNITION EXCITERS ARE DE-ENERGIZED FOR A MINIMUM OF FIVE MINUTES. ALSO DO NOT TOUCH THE ELECTRICAL CONTACTS. THE IGNITION SYSTEM VOLTAGE IS VERY HIGH, AND THE IGNITION EXCITERS CAN HAVE AN ELECTRICAL CHARGE EVEN WHEN NOT ENERGIZED. IF YOU DO NOT OBEY THESE PRECAUTIONS, INJURY CAN OCCUR.
ZONE: 400
FIN: 4000JH11
FIN: 4000JH12
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - PROTECTION
No specific
AR
COVER - PROTECTION
No specific
1
PLIERS - JAWED, SOFT
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR, 451AL, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
TASK 74-21-05-000-802-A
Removal of the Ignition Lead 1
TASK 78-30-00-040-809-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-36-00-010-806-A
Opening of the Thrust Reverser Cowl Doors
3. Job Set-up
Subtask 74-11-05-941-051-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put WARNING NOTICE(S) in position to tell persons not to operate:
  • The ENG/MODE selector switch, and
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 74-11-05-865-052-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1)
121VUENGINE/IGN/ENG1/SYS B3JH1P41
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2)
121VUENGINE/IGN/ENG2/SYS B3JH2P42
Subtask 74-11-05-010-052-A
C. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR.
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR.
Subtask 74-11-05-040-051-A
D. Deactivation of the Thrust Reverser System for Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-809).
Subtask 74-11-05-010-053-A
E. Get Access
   (1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR.
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR.
4. Procedure
Subtask 74-11-05-020-051-A
A. Removal of Ignition Exciter 1
   (1) Remove the four bolts (4) that attach the exciter box shroud lid (3) to the exciter box shroud (2).
   (2) Remove the exciter box shroud lid (3) from the exciter box shroud (2).
   (3) Remove the ignition lead 1 (5) (Ref. AMM TASK 74-21-05-000-802).
NOTE: Removal of the ignition lead 1 (5) allows enough flexibility to disconnect ignition lead 1 (5) from the ignition exciter 1 (1) without bending the ignition lead 1 (5) connection.
   (4) Disconnection of ignition lead 1 (5):
CAUTION: DO NOT TWIST OR BEND THE IGNITION LEADS. IF YOU DO, DAMAGE TO THE LEADS CAN OCCUR.
     (a) Disconnect the ignition lead 1 (5) B-nut from ignition exciter 1 (1).
   (5) Disconnect the electrical connector (6) from ignition exciter 1 (1). If necessary use PLIERS - JAWED, SOFT.
PRE SB 72-0402
   (6) Remove the four bolts (7) that attach ignition exciter 1 (1) to the exciter box shroud (2).
END of PRE SB 72-0402

POST SB 72-0402
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
   (7) Remove the bolt (7) and the bonding strap (8).
   (8) Remove the three bolts (7) that attach ignition exciter 1 (1) to the exciter box shroud (2).
END of POST SB 72-0402

   (9) Remove ignition exciter 1 (1) from the exciter box shroud (2).
   (10) Install COVER - PROTECTION and CAP - PROTECTION on all the open ports, open tubes, open hoses and connectors.