Removal of the T12 Sensor [CFML]
TASK 73-21-15-000-801-A
Removal of the T12 Sensor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 73-21-15-941-056-A
Subtask 73-21-15-020-050-A
[Rev.10 from 2021]
2026.04.01 12:58:22 UTC
Removal of the T12 Sensor
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
FIN: 4001KS
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - PROTECTION |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-60-42-000-801-A | Removal of the Air Intake Cowl T12 Access Panel |
Subtask 73-21-15-941-056-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 73-21-15-010-054-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) in position.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) in position.
Subtask 73-21-15-020-050-A
A. Removal of the T12 Sensor (1):
(1) Remove the T12 sensor access panel (2) (Ref. AMM TASK 71-60-42-000-801).
(2) Disconnection of the harness electrical connectors from the T12 sensor (1):
(b) Disconnect the HJ6B harness electrical connector (7) from the HJ6B harness receptacle (8).
(3) Remove the four bolts (9) and the four washers (10) that attach the T12 sensor (1) to the rear inlet bulkhead (4).
(4) Remove the four nuts (11) that attach the T12 sensor (1) to the mounting bracket (12) of the inlet case (3).
(5) Remove the T12 sensor (1) from the mounting bracket (12).
(6) Install COVER - PROTECTION and CAP - PROTECTION on all the open ports, open tubes, open hoses and connectors.
(1) Remove the T12 sensor access panel (2) (Ref. AMM TASK 71-60-42-000-801).
(2) Disconnection of the harness electrical connectors from the T12 sensor (1):
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
USE PLIERS THAT HAVE TEFLON JAWS TO TIGHTEN OR LOOSEN THE ELECTRICAL CONNECTORS. DO NOT USE PLIERS THAT HAVE METAL JAWS. METAL JAWS CAN CAUSE DAMAGE TO THE ELECTRICAL CONNECTORS.
(a) Disconnect the HJ6A harness electrical connector (5) from the HJ6A harness receptacle (6). (b) Disconnect the HJ6B harness electrical connector (7) from the HJ6B harness receptacle (8).
(3) Remove the four bolts (9) and the four washers (10) that attach the T12 sensor (1) to the rear inlet bulkhead (4).
(4) Remove the four nuts (11) that attach the T12 sensor (1) to the mounting bracket (12) of the inlet case (3).
(5) Remove the T12 sensor (1) from the mounting bracket (12).
(6) Install COVER - PROTECTION and CAP - PROTECTION on all the open ports, open tubes, open hoses and connectors.
T12 Sensor (4001KS)