Removal of the Air Intake Cowl T12 Access Panel [CFML]
TASK 71-60-42-000-801-A
Removal of the Air Intake Cowl T12 Access Panel
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 71-60-42-941-052-A
Subtask 71-60-42-020-050-A
[Rev.10 from 2021]
2026.04.01 12:58:22 UTC
Removal of the Air Intake Cowl T12 Access Panel
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 71-60-42-941-052-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-60-42-010-055-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position near the air inlet.
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position near the air inlet.
Subtask 71-60-42-020-050-A
A. Removal of the T12 Access Panel
(1) Remove the twelve screws (2).
(2) Remove the T12 access panel (1).
(1) Remove the twelve screws (2).
(2) Remove the T12 access panel (1).
Air Intake Cowl T12 Panel