Visual Inspection of the Manual Control Cover without Special Equipment [CFML]
TASK 72-63-03-210-801-A
Visual Inspection of the Manual Control Cover without Special Equipment
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-63-03-941-052-A
Subtask 72-63-03-210-050-A
Subtask 72-63-03-410-051-A
[Rev.10 from 2021]
2026.04.01 02:54:52 UTC
Visual Inspection of the Manual Control Cover without Special Equipment
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 72-63-03-100-801-A | Cleaning of the Manual-Control Cover of the Accessory Gearbox (AGB) |
Subtask 72-63-03-941-052-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 72-63-03-010-052-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
Subtask 72-63-03-210-050-A
A. Visual Inspection of the Manual Control Cover
(1) Make sure that the manual control cover (1) to be examined is clean (Ref. AMM TASK 72-63-03-100-801).
(2) Do a visual inspection of the external surfaces of all the removed components and other areas of the engine that are seen after the removal of the components. Refer to the table below for the inspection criteria.
5. Close-up(1) Make sure that the manual control cover (1) to be examined is clean (Ref. AMM TASK 72-63-03-100-801).
(2) Do a visual inspection of the external surfaces of all the removed components and other areas of the engine that are seen after the removal of the components. Refer to the table below for the inspection criteria.
| Examine | Maximum Serviceable Limits | Remarks |
|---|---|---|
| 1.Examine all the areas of the manual control cover (1) that are seen for: See the figure | | |
| A.Cracks | Not serviceable | |
| B.Corrosion | Not serviceable | |
| C.Missing surface protection for non - machined surfaces | Any amount, five percent of inside or outside protection | |
| D.Missing surface protection on all other areas | Not serviceable | |
| 2.Examine the seal groove for: | | |
| A.Scratches, nicks, dents and scores | Not serviceable | |
| 3.Examine all other areas that are seen for: | | |
| A.Scratches, nicks, dents and scores | Not serviceable | See repair (Ref. AMM D/O 72-63-03-35) |
Subtask 72-63-03-410-051-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(3) Remove the WARNING NOTICE(S).
Manual Control Cover