Removal of the Bosses [IAE]
TASK 72-50-50-000-801-A
Removal of the Bosses
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-50-50-941-052-A ** ON A/C NOT FOR ALL
Subtask 72-50-50-020-058-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:46:30 UTC
Removal of the Bosses
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 78-11-11-000-010-A | Removal of the Common Nozzle Assembly |
| TASK 78-11-12-000-010-A | Removal of the Engine Exhaust Cone |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
Subtask 72-50-50-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 72-50-50-010-060-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(2) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR.
Subtask 72-50-50-040-052-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(2) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR.
C. Deactivation of the Thrust Reverser
Subtask 72-50-50-010-061-A ** ON A/C NOT FOR ALL Subtask 72-50-50-010-062-A ** ON A/C NOT FOR ALL 4. ProcedureWARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Do the deactivation of the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). Subtask 72-50-50-020-058-A ** ON A/C NOT FOR ALL
A. Removal of the Bosses
(1) Remove the bolts (1) and the nuts (2).
(2) Remove the stop (3) from the boss (5).
(3) Remove the pins (4) from the boss (5).
(4) Remove the boss (5).
(1) Remove the bolts (1) and the nuts (2).
(2) Remove the stop (3) from the boss (5).
(3) Remove the pins (4) from the boss (5).
(4) Remove the boss (5).
Bosses