Inspection/Check of the Combustion Case Assembly [CFMB]
TASK 72-41-00-200-002-A
Inspection/Check of the Combustion Case Assembly
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-41-00-941-052-A ** ON A/C NOT FOR ALL
Subtask 72-41-00-230-052-A ** ON A/C NOT FOR ALL
Subtask 72-41-00-410-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:42:34 UTC
Inspection/Check of the Combustion Case Assembly
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 70-51-00-230-002-A | Fluorescent-Penetrant Inspection-Portable-Water Washable |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 72-00-00-200-025-A | Over-Serviceable-Limit Extensions |
| TASK 72-00-00-200-025-A-01 | Over-Serviceable-Limit Extensions |
| TASK 72-41-00-300-002-A | Repairs of the Combustion Case Assembly |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 72-41-00-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 72-41-00-010-054-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(2) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(3) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(4) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 72-41-00-040-052-A ** ON A/C NOT FOR ALL Subtask 72-41-00-010-056-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(2) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(3) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(4) Put an ACCESS PLATFORM 1M(3 FT) in position.
D. Open the thrust reverser cowl doors: (Ref. AMM TASK 78-36-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 72-41-00-230-052-A ** ON A/C NOT FOR ALL
A. Do a fluorecent penetrant inspection.
(1) When you do the visual inspection, if you find a crack or suspected crack in the combustion case assembly, you have to do the FPI to confirm the crack (Ref. AMM TASK 70-51-00-230-002).
Subtask 72-41-00-210-051-A ** ON A/C NOT FOR ALL (1) When you do the visual inspection, if you find a crack or suspected crack in the combustion case assembly, you have to do the FPI to confirm the crack (Ref. AMM TASK 70-51-00-230-002).
B. Do a visual inspection.
(1) Do the visual inspection that follows:
5. Close-up(1) Do the visual inspection that follows:
| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1.Combustion casing body for : | | |
| Not serviceable | |
| Any number 0.03 in. (0.76 mm) deep after removal of high metal | |
| Any number 0.10 in. (2.54 mm) deep after removal of high metal | |
| Not serviceable | |
| Any number, if metal not crazed. No cracks are permitted. | |
| 2.Combustion casing forward flanges for : | | |
| One crack per hole, 2 cracks per frame | |
| Not serviceable | See limit extensions (Ref. AMM TASK 72-00-00-200-025) |
| 3.Combustion case midflange for : | | |
| One broken bolt with a minimum of 5 bolts that are not broken on both sides of the broken bolt. No more than 2 broken bolts in any group of 20. | See limit extensions (Ref. AMM TASK 72-00-00-200-025) |
| 4.Combustion casing aft flange for : | | |
| One crack per hole, 2 cracks per frame | |
| Not serviceable | See limit extensions (Ref. AMM TASK 72-00-00-200-025) |
| 5.Fuel nozzle pads for : | | |
| Minimum of 4 undamaged threads must be present after chasing threads | |
| Any number on sealing surface 0.03 in. (0.76 mm) deep not extending across more than 50 percent of sealing surface after removal of high metal | Remove high metal and deposits (Ref. AMM TASK 72-41-00-300-002) |
| 6.Igniter and borescope bosses for : | | |
| Minimum of 3 undamaged threads must be present after chasing threads | |
| 7.HPT shroud cooling and CDP bleed pads for : | | |
| Any number, any length 0.03 in. (0.76 mm) in depth provided discrepancy does not extend over 75 percent of sealing surface | Remove high metal (Ref. AMM TASK 72-41-00-300-002). |
| One crack per hole no longer than 0.06 in. (1.52 mm) | See limit extensions (Ref. AMM TASK 72-00-00-200-025) |
Subtask 72-41-00-410-054-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl doors: (Ref. AMM TASK 78-36-00-410-040).
(3) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(4) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 72-41-00-440-052-A ** ON A/C NOT FOR ALL Subtask 72-41-00-410-056-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl doors: (Ref. AMM TASK 78-36-00-410-040).
(3) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(4) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Combustion Case Assembly