W DOC AIRBUS | AMM A320F

Inspection of the Screen [IAE]


TASK 72-32-60-200-010-A
Inspection of the Screen


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
This task is for V2500-A1 PRE SBE 72-0595 engines and V2500-A5 PRE SBE 70-0631 engines.
This task is not required for V2500-A1 POST SBE 72-0595 and V2500-A5 POST SBE 70-0631 engines.
This task gives the procedure for the inspection of the screen.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
IAE1J12187
1
COVER-PROTECTION LPC BLEED DUCT
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 72-32-60-000-010-A
Removal of the screen
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
3. Job Set-up
Subtask 72-32-60-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 72-32-60-010-050-A ** ON A/C NOT FOR ALL
B. Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 72-32-60-040-050-A ** ON A/C NOT FOR ALL
C. Deactivate the thrust reverser.
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Deactivate the thrust reverser hydraulic control unit (HCU) (Ref. AMM TASK 78-30-00-040-012).
Subtask 72-32-60-010-051-A ** ON A/C NOT FOR ALL
D. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
4. Procedure
Subtask 72-32-60-210-050-A ** ON A/C NOT FOR ALL
A. Visually examine the screen
F Screen ** ON A/C NOT FOR ALL
F Screen ** ON A/C NOT FOR ALL
CAUTION: IF THE SCREEN IS TORN OR THE SCREEN IS NOT INSTALLED, YOU MUST INSTALL A PLASTIC COVER OVER THE BLEED DUCT OUTLET WHEN MAINTENANCE WORK IS DONE IN THE ADJACENT AREA. YOU MUST MAKE SURE THAT THE COVER HAS A WARNING FLAG TO TELL PERSONS TO REMOVE THE COVER BEFORE THE ENGINE IS OPERATED.
   (1) Remove the cover, protection - LPC Bleed Duct (IAE1J12187) from the bleed duct outlet, if installed.
   (2) If the screen is torn, remove all loose fibers and accept it.
   (3) If the frame of the screen is damaged, but not cracked, accept it.
   (4) If the frame is cracked, remove the screen and accept it until the next shop visit (Ref. AMM TASK 72-32-60-000-010).
NOTE: Removal of the screen is acceptable for engine use until the next shop visit.
   (5) Install the cover, protection - LPC Bleed Duct (IAE1J12187) on the bleed duct outlet, if the screen is torn.
5. Close-up
Subtask 72-32-60-942-050-A ** ON A/C NOT FOR ALL
A. Remove the ground support equipment
CAUTION: YOU MUST MAKE SURE THAT YOU REMOVE THE PLASTIC COVER FROM THE BLEED DUCT OUTLET. IF YOU DO NOT DO THIS IT CAN CAUSE ENGINE SURGE AND DAMAGE WHEN THE ENGINE IS OPERATED.
   (1) Remove the IAE1J12187 COVER-PROTECTION LPC BLEED DUCT from the bleed duct outlet, if installed.
   (2) Remove the access platform(s).
Subtask 72-32-60-410-050-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 72-32-60-440-050-A ** ON A/C NOT FOR ALL
C. Activate the thrust reverser HCU (Ref. AMM TASK 78-30-00-440-012).
Subtask 72-32-60-410-051-A ** ON A/C NOT FOR ALL
D. Close Access
   (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:45:25 UTC