Removal of the Flowpath Panels 1 to 4 [CFML]
TASK 72-24-09-000-801-A
Removal of the Flowpath Panels 1 to 4
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-24-09-941-050-A
Subtask 72-24-09-020-050-A
[Rev.10 from 2021]
2026.04.01 02:53:06 UTC
Removal of the Flowpath Panels 1 to 4
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 78-30-00-040-809-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-36-00-010-806-A | Opening of the Thrust Reverser Cowl Doors |
Subtask 72-24-09-941-050-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 72-24-09-010-050-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 72-24-09-040-050-A (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
C. Deactivation of the Thrust Reverser System for Maintenance
Subtask 72-24-09-010-051-A WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-809). D. Get Access
(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR.
4. Procedure(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR.
Subtask 72-24-09-020-050-A
A. Removal of the Flowpath Panel 1
(1) Remove the two screws (3) that attach the flowpath panel 1 (2) to the fitting hanger (1).
(2) Remove the three screws (5) that attach the flowpath panel 1 (2) to the fan frame shroud (4).
(3) Remove the flowpath panel 1 (2).
(4) Install COVER - PROTECTION as necessary to prevent damage to the engine.
Subtask 72-24-09-020-051-A (1) Remove the two screws (3) that attach the flowpath panel 1 (2) to the fitting hanger (1).
(2) Remove the three screws (5) that attach the flowpath panel 1 (2) to the fan frame shroud (4).
(3) Remove the flowpath panel 1 (2).
(4) Install COVER - PROTECTION as necessary to prevent damage to the engine.
B. Removal of the Flowpath Panel 2
(1) Remove the eight bolts (7) and the eight washers (15) that attach the flowpath panel 2 (6) to the fan frame shroud (4).
(2) Remove the eight screws (8) that attach the flowpath panel 2 (6) to the fan frame shroud (4).
(3) Remove the flowpath panel 2 (6).
(4) Install COVER - PROTECTION as necessary to prevent damage to the engine.
Subtask 72-24-09-020-052-A (1) Remove the eight bolts (7) and the eight washers (15) that attach the flowpath panel 2 (6) to the fan frame shroud (4).
(2) Remove the eight screws (8) that attach the flowpath panel 2 (6) to the fan frame shroud (4).
(3) Remove the flowpath panel 2 (6).
(4) Install COVER - PROTECTION as necessary to prevent damage to the engine.
C. Removal of the Flowpath Panel 3
(1) Remove the seven bolts (10) and the seven washers (16) that attach the flowpath panel 3 (9) to the fan frame shroud (4).
(2) Remove the seven screws (11) that attach the flowpath panel 3 (9) to the fan frame shroud (4).
(3) Remove the flowpath panel 3 (9).
(4) Install COVER - PROTECTION as necessary to prevent damage to the engine.
Subtask 72-24-09-020-053-A (1) Remove the seven bolts (10) and the seven washers (16) that attach the flowpath panel 3 (9) to the fan frame shroud (4).
(2) Remove the seven screws (11) that attach the flowpath panel 3 (9) to the fan frame shroud (4).
(3) Remove the flowpath panel 3 (9).
(4) Install COVER - PROTECTION as necessary to prevent damage to the engine.
D. Removal of the Flowpath Panel 4
(1) Remove the two screws (13) that attach the flowpath panel 4 (12) to the fitting hanger (1).
(2) Remove the three screws (14) that attach the flowpath panel 4 (12) to the fan frame shroud (4).
(3) Remove the flowpath panel 4 (12).
(4) Install COVER - PROTECTION as necessary to prevent damage to the engine.
(1) Remove the two screws (13) that attach the flowpath panel 4 (12) to the fitting hanger (1).
(2) Remove the three screws (14) that attach the flowpath panel 4 (12) to the fan frame shroud (4).
(3) Remove the flowpath panel 4 (12).
(4) Install COVER - PROTECTION as necessary to prevent damage to the engine.
Flowpath Panels 1 to 4