W DOC AIRBUS | AMM A320F

Wire Continuity Check - All Power Plant Electrical Cables [IAE]


TASK 71-50-00-220-010-A
Wire Continuity Check - All Power Plant Electrical Cables


1. Reason for the Job
This procedure is applicable to all power plant electrical cables. This procedure provides the information necessary to accomplish a contact pin (or socket) to contact pin (or socket) electrical wire continuity check.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
MULTIMETER MODEL 160B
No specific
AR
OHMMETER MODEL 260
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
3. Job Set-up
Subtask 71-50-00-941-054-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 71-50-00-010-057-A ** ON A/C NOT FOR ALL
B. Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 71-50-00-040-054-A ** ON A/C NOT FOR ALL
C. Deactivate the thrust reverser.
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Deactivate the thrust reverser hydraulic control unit (HCU) (Ref. AMM TASK 78-30-00-040-012).
Subtask 71-50-00-010-060-A ** ON A/C NOT FOR ALL
D. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
4. Procedure
Subtask 71-50-00-020-050-A ** ON A/C NOT FOR ALL
A. Disconnect the two connectors of the wire harness which contains the cable of the circuit to be checked.
Subtask 71-50-00-220-050-A ** ON A/C NOT FOR ALL
B. Wire continuity check.
CAUTION: DO NOT CAUSE DAMAGE TO CONNECTOR PINS WHEN YOU DO CONTINUITY CHECKS. DAMAGED PINS CAN BECOME LOOSE AND CAN THUS INTERMITTENTLY PREVENT CORRECT CONTINUITY.
   (1) Do a wire continuity check on the suspect contacts/wire from point-to-point (end to end). Use a MULTIMETER MODEL 160B or OHMMETER MODEL 260 or equivalent.
   (2) Each circuit must have continuity from one end of the wire to the other end of the wire.
   (3) Defective circuits must be repaired (ref. AMM 70-71-00 Pb 001)
Subtask 71-50-00-420-050-A ** ON A/C NOT FOR ALL
C. Connect all the connectors and secure.
5. Close-up
Subtask 71-50-00-410-057-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
   (3) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
   (4) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 71-50-00-440-054-A ** ON A/C NOT FOR ALL
B. Activate the thrust reverser HCU (Ref. AMM TASK 78-30-00-440-012).
Subtask 71-50-00-410-060-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
   (2) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
   (3) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:30:36 UTC