General Visual Examination of the Aft Engine Mount [IAE]
TASK 71-22-11-200-011-A
General Visual Examination of the Aft Engine Mount
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-22-11-941-051-A ** ON A/C NOT FOR ALL
Subtask 71-22-11-210-052-A ** ON A/C NOT FOR ALL
Subtask 71-22-11-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:30:28 UTC
General Visual Examination of the Aft Engine Mount
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
Subtask 71-22-11-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 71-22-11-010-053-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 2M (6 FT) in to position.
Subtask 71-22-11-040-051-A ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 2M (6 FT) in to position.
C. Deactivate the thrust reverser.
Subtask 71-22-11-010-054-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Deactivate the thrust reverser hydraulic control unit (HCU) (Ref. AMM TASK 78-30-00-040-012). D. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 71-22-11-210-052-A ** ON A/C NOT FOR ALL
A. Examine the aft engine mount
(1) Visually examine the link assemblies for security of attachment to the turbine case and to the mount beam assembly. Reject any loose or missing fasteners.
(2) Visually examine all of the anti-rotation and retainer plates for any obvious damage and security of attachment. Reject any loose or missing fasteners.
(3) Visually examine the mount assembly for cracks and other obvious damage. Reject any damaged parts.
5. Close-up(1) Visually examine the link assemblies for security of attachment to the turbine case and to the mount beam assembly. Reject any loose or missing fasteners.
(2) Visually examine all of the anti-rotation and retainer plates for any obvious damage and security of attachment. Reject any loose or missing fasteners.
(3) Visually examine the mount assembly for cracks and other obvious damage. Reject any damaged parts.
Subtask 71-22-11-410-053-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(3) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
(4) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 71-22-11-440-051-A ** ON A/C NOT FOR ALL Subtask 71-22-11-410-054-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(3) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
(4) FOR [1000EM2] (ENGINE-2)
461AL 462AR.