W DOC AIRBUS | AMM A320F

General Visual Inspection of Fan Cowl Door Hinges and Surrounding Structure (150 mm (5.91 in.) around Hinge Fittings) [CFML]


TASK 71-13-46-210-801-A
General Visual Inspection of Fan Cowl Door Hinges and Surrounding Structure (150 mm (5.91 in.) around Hinge Fittings)


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the Job
Refer to the MPD TASK: 711321-01
GENERAL VISUAL INSPECTION OF FAN COWL DOORS HINGES AND SURROUNDING STRUCTURE (150MM AROUND HINGE FITTINGS).
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-803-A
Closing of the Fan Cowl Doors
NSRM 542001
3. Job Set-up
Subtask 71-13-46-941-054-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put a WARNING NOTICE(S) in position to tell persons not to operate:
  • The ENG/MODE selector switch
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-13-46-010-054-A
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (2) Put an ACCESS PLATFORM 2M (6 FT) in position.
4. Procedure
Subtask 71-13-46-210-050-A
A. General Visual Inspection of Fan Cowl Door Hinge Fittings and Surroundings
   (1) Examine every hinge fitting structure for cracks, dents, wear, corrosion, missing or loose fasteners or broken parts. If external damages are found, refer to NSRM 542001.
   (2) Examine surrounding structure for cracks, dents, wear, corrosion, missing or loose fasteners or broken parts. If external damages are found, refer to NSRM 542001.
     (a) Do a check of the bolts, washers, nuts and bushes.
     (b) Examine the fan cowl door forward and aft flanges.
     (c) Examine the fan cowl door surrounding inner surface.
     (d) Check the F1 hinge beam.
5. Close-up
Subtask 71-13-46-410-051-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl-doors (Ref. AMM TASK 71-13-00-410-803).
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:35:29 UTC