W DOC AIRBUS | AMM A320F

Emergency Procedures in case of Engine Fire [IAE]


TASK 71-00-00-710-023-A
Emergency Procedures in case of Engine Fire


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 29-10-00-710-001-A
Operational Check of Hydraulic Fire Shut Off Valves and Associated Indicating System
TASK 71-00-00-860-014-A
Procedure After the Use of Fire Extinguishing Agents
3. Job Set-up
Subtask 71-00-00-869-310-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Procedure
Subtask 71-00-00-869-311-A ** ON A/C NOT FOR ALL
A. Do these Procedures as Necessary
CAUTION: TRY TO EXTINGUISH INTERNAL FIRES BY MOTORING THE ENGINE FIRST. USE FIRE EXTINGUISHING AGENTS ONLY WHEN MOTORING DOES NOT WORK. IF EXTINGUISHING AGENTS ARE USED, A MAJOR INSPECTION CAN BE NECESSARY.
   (1) Internal engine fire
NOTE: An internal engine fire (post-shutdown burning), can be identified by a failure of the EGT to go down after placing ENG MASTER 1(2) switch in the OFF position.
     (a) When an internal engine fire occurs during ground operation, do this procedure:
       1 1 Quickly and immediately move the throttle control lever to the idle position.
       2 On the ENG panel 115VU:
  • Set the ENG/MASTER 1(2) switch to OFF.
       3 On the ENG panel 115VU:
  • Set the ENG/MODE/CRANK/NORM/IGN/START selector switch to CRANK.
       4 On the overhead CTL & IND panel 22VU:
  • Push the ENG/MAN START/1(2) pushbutton switch.
NOTE: The start valve will automatically reopens when N2 is below 10 percent.
       5 Ignore the starter time limits and dry motor the engine until you remove all indications of a fire.
       6 When fire is extinguished (confirmed by ground crew):
         a On the overhead CTL & IND panel 22VU:
  • Release the ENG/MAN START/1(2) pushbutton switch.
         b On the ENG panel 115VU:
  • Set the ENG/MODE/CRANK/NORM/IGN/START selector switch to NORM.
       7 If you cannot extinguish the fire with a motoring of the engine or if the motoring is not possible:
  • Press the ENG FIRE pushbutton switch to ON to close the LP shut off valve and extinguish the fire with ground equipment.
   (2) External engine fire
NOTE: (1) The warnings below operate when there is an external engine fire:
(a) On the ENG/APU FIRE panel 1WD:
- The ENG 1(2) FIRE legend of the pushbutton switch comes on.
(b) The continuous repetitive chime operates.
(c) The MASTER WARN lights come on.

(2) On the upper ECAM display unit:
- A message and the applicable procedure come into view.
(a) On the ENG panel 115VU:
- The applicable FIRE legend comes on.
NOTE: A fire detected by the fire detection loops can be extinguished by portable or onboard fire-extinguishing systems.
     (a) When there is an external engine fire, do this procedure:
       1 Put the throttle control levers of the engines 1 and 2 in the idle stop position (zero on the graduated sector).
       2 On the ENG panel 115VU:
  • Set the ENG/MASTER 1(2) switch to OFF.
       3 On the ENG/APU FIRE panel 1WD, push the ENG 1(2) FIRE pushbutton switch:
  • The SQUIB legends of the applicable AGENT 1 and AGENT 2 pushbutton switches come on.
  • The audio warning stops.
       4 On the ENG/APU FIRE panel 1WD, push the AGENT 1 and 2 pushbutton switches:
  • After not many seconds, the DISCH legends of the pushbutton switches comes on.
     (b) Open the cowl doors and extinguish the fire with a fire extinguisher if this procedure does not completely stop the fire.
     (c) If fire occurs in fan zone with fan cowl doors opened, use the fire extinguishers that are on the ground, when permitted to do so by the approved person.
NOTE: The aircraft fire extinguishers do not have an effect with the cowls open or removed.
     (d) Replace the nacelle fire extinguisher bottles if they are used.
5. Close-up
Subtask 71-00-00-100-050-A ** ON A/C NOT FOR ALL
A. When the fire is extinguished, do the procedure after the use of Fire Extinguishing Agents (Ref. AMM TASK 71-00-00-860-014)
Subtask 71-00-00-710-231-A ** ON A/C NOT FOR ALL
B. After operation of the ENG1(2) FIRE pushbutton switch, do the operational test of the hydraulic fire shut off valves (Ref. AMM TASK 29-10-00-710-001).
[Rev.10 from 2021] 2026.04.01 02:28:12 UTC