Operational Check of Hydraulic Fire Shut Off Valves and Associated Indicating System
TASK 29-10-00-710-001-A
Operational Check of Hydraulic Fire Shut Off Valves and Associated Indicating System
1. Reason for the Job
Refer to the MPD TASK: 291000-09
OPERATIONAL CHECK OF HYDRAULIC FIRE SHUT OFF VALVES AND ASSOCIATED INDICATING SYSTEM.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-10-00-860-071-A
Subtask 29-10-00-710-050-C ** ON A/C NOT FOR ALL
Subtask 29-10-00-860-072-A
[Rev.10 from 2021]
2026.04.01 00:14:06 UTC
Operational Check of Hydraulic Fire Shut Off Valves and Associated Indicating System
1. Reason for the Job
Refer to the MPD TASK: 291000-09
OPERATIONAL CHECK OF HYDRAULIC FIRE SHUT OFF VALVES AND ASSOCIATED INDICATING SYSTEM.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | AMMETER - DIGITAL |
| FOR [1046GK] (FIRE-S.-O.V.) | ||
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| FOR [3046GD] (FIRE-S.-O.V.) | ||
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 574 | FALSE SPAR BOX |
| 674 | FALSE SPAR BOX |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| FOR [1046GK] (FIRE-S.-O.V.) | |
| 574AB | |
| FOR [3046GD] (FIRE-S.-O.V.) | |
| 674AB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 29-11-52-000-001-A | Removal of the Engine Pump Fire-Valve |
| TASK 29-11-52-400-001-A | Installation of the Engine Pump Fire-Valve |
| TASK 29-13-52-000-001-A | Removal of the Engine Pump Fire-Valve |
| TASK 29-13-52-400-001-A | Installation of the Engine Pump Fire-Valve |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 29-10-00-860-071-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(Ref. AMM TASK 31-60-00-860-001) .
(3) On the ECAM control panel, push the HYD key. Make sure that the HYD page comes into view on the ECAM lower DU.
Subtask 29-10-00-865-077-A (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
NOTE: Do not use the ref. task 24-41-00-861-002-A-02 to energize the aircraft electrical circuits.
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)(Ref. AMM TASK 31-60-00-860-001) .
(3) On the ECAM control panel, push the HYD key. Make sure that the HYD page comes into view on the ECAM lower DU.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-10-00-010-065-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/FIRE VALVE/Y/ENG2 | 3702GD | C14 |
| 49VU | HYD/FIRE VALVE/G/ENG1 | 1703GK | C13 |
C. Get Access
(1) FOR [1046GK] (FIRE-S.-O.V.)
(a) Put the ACCESS PLATFORM 3M (10 FT) in position below the access panel 574AB.
(b) Open access panel 574AB.
(2) FOR [3046GD] (FIRE-S.-O.V.)
(a) Put the ACCESS PLATFORM 3M (10 FT) in position below the access panel 674AB.
(b) Open access panel 674AB.
Subtask 29-10-00-010-065-B ** ON A/C NOT FOR ALL (1) FOR [1046GK] (FIRE-S.-O.V.)
(a) Put the ACCESS PLATFORM 3M (10 FT) in position below the access panel 574AB.
(b) Open access panel 574AB.
(2) FOR [3046GD] (FIRE-S.-O.V.)
(a) Put the ACCESS PLATFORM 3M (10 FT) in position below the access panel 674AB.
(b) Open access panel 674AB.
C. Get Access
(1) FOR [1046GK] (FIRE-S.-O.V.)
(a) Put the ACCESS PLATFORM 3M (10 FT) in position below access panel 574AB.
(b) Open access panel 574AB.
(2) FOR [3046GD] (FIRE-S.-O.V.)
(a) Put the ACCESS PLATFORM 3M (10 FT) in position below the access panel 674AB.
(b) Open access panel 674AB.
(3) FOR [1000EM1] (ENGINE-1)
(a) Open access doors 437AL and 438AR.
(4) FOR [1000EM2] (ENGINE-2)
(a) Open access doors 447AL and 448AR.
4. Procedure(1) FOR [1046GK] (FIRE-S.-O.V.)
(a) Put the ACCESS PLATFORM 3M (10 FT) in position below access panel 574AB.
(b) Open access panel 574AB.
(2) FOR [3046GD] (FIRE-S.-O.V.)
(a) Put the ACCESS PLATFORM 3M (10 FT) in position below the access panel 674AB.
(b) Open access panel 674AB.
(3) FOR [1000EM1] (ENGINE-1)
(a) Open access doors 437AL and 438AR.
(4) FOR [1000EM2] (ENGINE-2)
(a) Open access doors 447AL and 448AR.
Subtask 29-10-00-710-050-C ** ON A/C NOT FOR ALL
A. Do this test.
Subtask 29-10-00-710-050-D ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.On the ENG/APU FIRE panel 1WD of the overhead panel 20VU: | |
| The single chime audio warning operates. |
| | On the glareshield panels 130VU and 131VU:
|
| | On the ECAM lower DU:
|
| | On the fire shut-off valve (1046GK/3046GD):
|
| 2.On the ENG/APU FIRE panel 1WD of the overhead panel 20VU: | On the glareshield panels 130VU and 131VU: |
|
|
| | On the ECAM lower DU:
|
| | On the fire shut-off valve (1046GK/3046GD):
|
| |
WARNING:
BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS. THERE IS A HIGH VOLTAGE BEHIND THESE PANELS. 3.Open the overhead panel 49VU to get access to the pins of the circuit breaker 1703GK (3702GD). | |
| 4.Connect a AMMETER - DIGITAL (with a range of less than 500 mA) between the terminal 1 and terminal 2 of the circuit breaker 1703GK (3702GD) with alligator clips. NOTE: Make sure that the digital ammeter is correctly calibrated. | |
| 5.Open the circuit breaker 1703GK (3702GD). | |
| 6.Make sure that the ammeter shows 0 mA. NOTE: Take into account the tolerance of the digital ammeter. NOTE: If the ammeter does not show 0 mA, replace the fire shut-off valve 1046GK (3046GD) (Ref. AMM TASK 29-11-52-000-001) and (Ref. AMM TASK 29-11-52-400-001) or ( (Ref. AMM TASK 29-13-52-000-001)) and ( (Ref. AMM TASK 29-13-52-400-001)). NOTE: With a permanent operation of the electrical motor of the fire shut-off valve, because of an incomplete opening of the valve, the current range can be from 25 mA (clutch worn) to 400 mA. | |
| 7.Disconnect the ammeter. | |
| 8.Close the circuit breaker 1703GK (3702GD) | |
| 9.Install the overhead panel. | |
A. Do this test.
Subtask 29-10-00-710-050-E ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.On the ENG/APU FIRE panel 1WD of the overhead panel 20VU: | |
| The single chime audio warning operates. |
| | On the glareshield panels 130VU and 131VU:
|
| | On the ECAM lower DU:
|
| | On the fire shut-off valve (1046GK/3046GD):
|
| 2.On the ENG/APU FIRE panel 1WD of the overhead panel 20VU: | On the glareshield panels 130VU and 131VU: |
|
|
| | On the ECAM lower DU:
|
| | On the fire shut-off valve (1046GK/3046GD):
|
| |
WARNING:
BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS. THERE IS A HIGH VOLTAGE BEHIND THESE PANELS. 3.Open the overhead panel 49VU to get access to the pins of the circuit breaker 1703GK (3702GD). | |
| 4.Connect a AMMETER - DIGITAL (with a range of less than 500 mA) between the terminal 1 and terminal 2 of the circuit breaker 1703GK (3702GD) with alligator clips. NOTE: Make sure that the digital ammeter is correctly calibrated. | |
| 5.Open the circuit breaker 1703GK (3702GD). | |
| 6.Make sure that the ammeter shows 0 mA. NOTE: Take into account the tolerance of the digital ammeter. NOTE: If the ammeter does not show 0 mA, replace the fire shut-off valve 1046GK (3046GD) (Ref. AMM TASK 29-11-52-000-001) and (Ref. AMM TASK 29-11-52-400-001) or ( (Ref. AMM TASK 29-13-52-000-001)) and ( (Ref. AMM TASK 29-13-52-400-001)). NOTE: With a permanent operation of the electrical motor of the fire shut-off valve, because of an incomplete opening of the valve, the current range can be from 25 mA (clutch worn) to 400 mA. | |
| 7.Disconnect the ammeter. | |
| 8.Close the circuit breaker 1703GK (3702GD) | |
| 9.Install the overhead panel. | |
A. Do this test
5. Close-up| ACTION | RESULT |
|---|---|
| 1.Open overhead panel 49VU to get access to the pins of circuit breaker 1711GK (3712GD). WARNING:
BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS. THERE IS A HIGH VOLTAGE BEHIND THESE PANELS. 2.Open circuit breaker 1711GK (3712GD) - location H14 (H13). | |
| 3.On ENG/APU FIRE panel 1WD of overhead panel 20VU: | |
| The single chime audio warning operates. |
| | On glareshield panels 130VU and 131VU:
|
| | On the ECAM lower DU:
|
| | On the fire shut-off valve (1046GK/3046GD):
|
| 4.On the ENG/APU FIRE panel 1WD of overhead panel 20VU: | On glareshield panels 130VU and 131VU: |
|
|
| | On the ECAM lower DU:
|
| | On the fire shut-off valve (1046GK/3046GD):
|
| |
WARNING:
BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS. THERE IS A HIGH VOLTAGE BEHIND THESE PANELS. 5.Close circuit breaker 1711GK (3712GD) - location H14 (H13). | |
WARNING:
BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS. THERE IS A HIGH VOLTAGE BEHIND THESE PANELS. 6.Open circuit breaker 1703GK (3702GD) and wait for a few seconds. | On the fire shut-off valve (1046GK/3046GD):
|
WARNING:
BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS. THERE IS A HIGH VOLTAGE BEHIND THESE PANELS. 7.Close circuit breaker 1703GK (3702GD) and wait for a few seconds. | On the fire shut-off valve (1046GK/3046GD):
|
| 8.Open circuit breaker 1711GK (3712GD) - location H14 (H13). | |
| 9.Open the access door of relay box 103VU. | |
| 10.Disconnect relay 1725GK (3724GD). | |
| 11.Connect the AMMETER - DIGITAL (with a range of less than 500 mA) between the terminal 1 and terminal 2 of circuit breaker 1703GK (3702GD) with alligator clips. NOTE: Make sure that the digital ammeter is correctly calibrated. | |
| 12.Open circuit breaker 1703GK (3702GD). | |
| 13.Make sure that the digital ammeter shows less than 25 mA. NOTE: Take into account the tolerance of the digital ammeter. | |
| 14.If the digital ammeter shows more than 25 mA, replace fire shut-off valve 1046GK (3046GD) (Ref. AMM TASK 29-11-52-000-001) (Ref. AMM TASK 29-11-52-400-001) (Ref. AMM TASK 29-13-52-000-001) (Ref. AMM TASK 29-13-52-400-001). NOTE: With a permanent operation of the electrical motor of the fire shut-off valve, because of an incomplete opening of the valve, the current range can be from 25 mA (clutch worn) to 400 mA. | |
| 15.Disconnect the digital ammeter. | |
| 16.Close circuit breaker 1703GK (3702GD). | |
| 17.Connect relay 1725GK (3724GD). | |
| 18.Close the access door of relay box 103VU. | |
| 19.Close circuit breaker 1711GK (3712GD) - location H14 (H13). | |
| 20.Install overhead panel 49VU. | |
Subtask 29-10-00-860-072-A
A. Put the aircraft back to the serviceable condition.
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002)
(2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 29-10-00-410-065-A ** ON A/C NOT FOR ALL (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002)
(2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [1046GK] (FIRE-S.-O.V.)
(a) Close access panel 574AB.
(3) FOR [3046GD] (FIRE-S.-O.V.)
(a) Close access panel 674AB.
(4) Remove the access platform(s).
Subtask 29-10-00-410-065-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [1046GK] (FIRE-S.-O.V.)
(a) Close access panel 574AB.
(3) FOR [3046GD] (FIRE-S.-O.V.)
(a) Close access panel 674AB.
(4) Remove the access platform(s).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [1000EM1] (ENGINE-1)
(a) Close access doors 437AL and 438AR.
(3) FOR [1000EM2] (ENGINE-2)
(a) Close access doors 447AL and 448AR.
(4) FOR [1046GK] (FIRE-S.-O.V.)
(a) Close access panel 574AB.
(5) FOR [3046GD] (FIRE-S.-O.V.)
(a) Close access panel 674AB.
(6) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [1000EM1] (ENGINE-1)
(a) Close access doors 437AL and 438AR.
(3) FOR [1000EM2] (ENGINE-2)
(a) Close access doors 447AL and 448AR.
(4) FOR [1046GK] (FIRE-S.-O.V.)
(a) Close access panel 574AB.
(5) FOR [3046GD] (FIRE-S.-O.V.)
(a) Close access panel 674AB.
(6) Remove the access platform(s).