W DOC AIRBUS | AMM A320F

Installation of the Access Panel


TASK 57-41-37-400-003-A
Installation of the Access Panel


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 522
ZONE: 622
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SCRAPER - NON METALLIC
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.06AAB1)
Polysulfide Sealant-General Purpose Fillet -
(Material No.06AAC1)
Polysulfide Sealant-General Purpose Interfay -
(Material No.06ABB2)
Polysulfide Sealant-Fuel Tank Fillet 120 degre Celsius
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14DBB1)
Release Agent-- Liquid Wax -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
522
OUTBOARD FIXED L.E STRUCTURE
622
OUTBOARD FIXED L.E STRUCTURE
522AT, 622AT
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 20-21-11-911-001-A
Tightening Torques for Standard Threaded Fasteners
TASK 27-80-00-866-004-A
Extending the Slats on the Ground
TASK 27-80-00-866-005-A
Retracting the Slats on the Ground
3. Job Set-up
Subtask 57-41-37-941-061-A
A. Safety Precautions
   (1) Make sure that the SAFETY BARRIER(S) are in position.
   (2) Make sure that the slats are fully extended (Ref. AMM TASK 27-80-00-866-004).
   (3) Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is installed on the flap/slat control lever.
   (4) Make sure that the WARNING NOTICE(S) is in position in the cockpit to tell persons not to operate the slats.
   (5) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the applicable access panel 522AT(622AT).
Subtask 57-41-37-865-070-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB06
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB01
** ON A/C ALL
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
4. Procedure
Subtask 57-41-37-210-057-A
A. Preparation for Installation
   (1) Do an inspection of the component interfaces and the adjacent area.
   (2) Use a SCRAPER - NON METALLIC and a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean:
  • the interface of the aircraft structure
  • the mating surfaces of the access panel (2).
   (3) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the interface of the aircraft structure.
   (4) Apply Release Agent-- Liquid Wax - (Material No.14DBB1) to the mating surfaces of the access panel (2).
   (5) Make sure that the work area is clean and clear of tools and other items.
Subtask 57-41-37-420-054-B ** ON A/C NOT FOR ALL
B. Installation of Access Panel 522AT( 622AT)
CAUTION: MAKE SURE THAT THE ACCESS PANEL SCREWS ARE INSTALLED IN THEIR CORRECT POSITIONS. INCORRECT INSTALLATION OF THE SCREWS CAN CAUSE DAMAGE TO THE SLATS DURING SLAT MOVEMENT.
   (1) Hold the access panel (2) in position.
   (2) Loosely install the bolts in their correct positions as follows:
  • The bolts (1), (7) and (8)
  • The bolts (5)
  • The bolt (4)
  • The bolt (3)
  • The bolt (6).
   (3) Tighten the bolts gradually (Ref. AMM TASK 20-21-11-911-001).
   (4) Make sure that the access panel (2) is correctly aligned with the adjacent panels.
   (5) Apply Polysulfide Sealant-General Purpose Fillet - (Material No.06AAB1) in the space between the access panel (2) and the adjacent surface.
Subtask 57-41-37-420-054-C ** ON A/C NOT FOR ALL
B. Installation of Access Panel 522AT( 622AT)
CAUTION: MAKE SURE THAT THE ACCESS PANEL SCREWS ARE INSTALLED IN THEIR CORRECT POSITIONS. INCORRECT INSTALLATION OF THE SCREWS CAN CAUSE DAMAGE TO THE SLATS DURING SLAT MOVEMENT.
   (1) Hold the access panel (2) in position.
   (2) Loosely install the bolts in their correct positions as follows:
  • The bolts (1), (7) and (8)
  • The bolts (5)
  • The bolt (4)
  • The bolt (3)
  • The bolt (6).
   (3) Tighten the bolts gradually (Ref. AMM TASK 20-21-11-911-001).
   (4) Make sure that the access panel (2) is correctly aligned with the adjacent panels.
   (5) Apply Polysulfide Sealant-Fuel Tank Fillet 120 degre Celsius (Material No.06ABB2) in the space between the access panel (2) and the adjacent surface.
5. Close-up
Subtask 57-41-37-865-071-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB06
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB01
** ON A/C ALL
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
Subtask 57-41-37-410-059-A
B. Close Access
   (1) Remove the access platform(s).
   (2) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the flap/slat control lever.
   (3) Retract the slats (Ref. AMM TASK 27-80-00-866-005).
Subtask 57-41-37-942-059-A
C. Removal of Equipment
   (1) Remove the safety barriers.
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.01 03:53:25 UTC