Installation of the Rear Mount Fairing (RMF) Door
TASK 54-57-22-400-810-A
Installation of the Rear Mount Fairing (RMF) Door
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 54-57-22-941-075-B ** ON A/C NOT FOR ALL
Subtask 54-57-22-420-066-B ** ON A/C NOT FOR ALL
Subtask 54-57-22-440-058-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:52:51 UTC
Installation of the Rear Mount Fairing (RMF) Door
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 470 | ENGINE 1 AFT PYLON |
| 480 | ENGINE 2 AFT PYLON |
| 473AL, 473AR, 483AL, 483AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
Subtask 54-57-22-941-075-B ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(2) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
Subtask 54-57-22-040-062-B ** ON A/C NOT FOR ALL (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(2) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
B. Deactivation of the Thrust Reverser
Subtask 54-57-22-110-050-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make sure that the thrust reverser is unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805). C. Preparation for Installation
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the parts retained from the removed component with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
(3) Do an inspection of the component interfaces and the adjacent area.
4. Procedure(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the parts retained from the removed component with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 54-57-22-420-066-B ** ON A/C NOT FOR ALL
A. Installation of the Rear Mount Fairing (RMF) Door
(2) Install the screws (1) and tighten them.
Subtask 54-57-22-820-055-B ** ON A/C NOT FOR ALL NOTE: The procedure is the same for all the RMF doors:
(1) Put and hold the RMF door (2) in position. (2) Install the screws (1) and tighten them.
B. Check of the Clearances
(1) Make sure that the peripheral clearance J1 between the APF (1) and the RMF door (2) is 4.2 +2 mm or -2 mm (0.1654 +0.0787 in. or -0.0787 in.).
(2) Make sure that the out-of-flush dimension A1 between the APF (1) and the RMF door (2) is 0 +0.7 mm or -0.5 mm (0.0000 +0.0276 in. or -0.0197 in.).
5. Close-up(1) Make sure that the peripheral clearance J1 between the APF (1) and the RMF door (2) is 4.2 +2 mm or -2 mm (0.1654 +0.0787 in. or -0.0787 in.).
(2) Make sure that the out-of-flush dimension A1 between the APF (1) and the RMF door (2) is 0 +0.7 mm or -0.5 mm (0.0000 +0.0276 in. or -0.0197 in.).
Subtask 54-57-22-440-058-B ** ON A/C NOT FOR ALL
A. Reactivation of the Thrust Reverser
(1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 54-57-22-942-057-B ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-805).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
RMF Door