Closing of the Rear Mount Fairing (RMF) Door
TASK 54-56-11-410-801-A
Closing of the Rear Mount Fairing (RMF) Door
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 54-56-11-941-051-A ** ON A/C NOT FOR ALL
Subtask 54-56-11-410-050-A ** ON A/C NOT FOR ALL
Subtask 54-56-11-440-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:49:48 UTC
Closing of the Rear Mount Fairing (RMF) Door
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 470 | ENGINE 1 AFT PYLON |
| 480 | ENGINE 2 AFT PYLON |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
Subtask 54-56-11-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(2) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
Subtask 54-56-11-040-051-A ** ON A/C NOT FOR ALL (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(2) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
B. Deactivation of the Thrust Reverser
4. ProcedureWARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make sure that the thrust reverser is unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805). Subtask 54-56-11-410-050-A ** ON A/C NOT FOR ALL
A. Closing of the Rear Mount Fairing (RMF) Door
(1) Make sure that the RMF door is clean and in the correct condition.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Close the RMF door (4).
(4) Install the screws (5), (3), (2) and (1) and tighten them.
5. Close-up(1) Make sure that the RMF door is clean and in the correct condition.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Close the RMF door (4).
(4) Install the screws (5), (3), (2) and (1) and tighten them.
Subtask 54-56-11-440-050-A ** ON A/C NOT FOR ALL
A. Reactivation of the Thrust Reverser
(1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 54-56-11-942-050-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-805).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Rear Mount Fairing (RMF) Door