W DOC AIRBUS | AMM A320F

Installation of the Pressure Relief Door


TASK 54-53-11-400-805-A
Installation of the Pressure Relief Door


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 470
ZONE: 480
FIN: 4020KM1
FIN: 4020KM2
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.06ABB2)
Polysulfide Sealant-Fuel Tank Fillet 120 degre Celsius
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
470
ENGINE 1 AFT PYLON
480
ENGINE 2 AFT PYLON
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 20-28-00-912-802-A
Electrical Bonding - General Maintenance Procedure
TASK 78-30-00-040-807-A
Deactivation of the Thrust Reverser System for Nacelle Maintenance (ICU)
TASK 78-30-00-440-807-A
Reactivation of the Thrust Reverser System after Nacelle Maintenance (ICU)
3. Job Set-up
Subtask 54-53-11-941-066-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
     (a) For the left pylon, in zone 470
     (b) For the right pylon, in zone 480.
Subtask 54-53-11-040-064-A
B. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make sure that the thrust reverser is unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-807).
Subtask 54-53-11-110-052-A
C. Preparation for Installation
   (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (2) Clean the parts retained from the removed component with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
   (3) Do an inspection of the component interfaces and the adjacent area.
4. Procedure
Subtask 54-53-11-420-058-A
A. Installation of the Pressure Relief Door
CAUTION: MAKE SURE THAT YOU INSTALL EACH OF THE SCREWS IN ITS CORRECT POSITION. THE SCREWS HAVE DIFFERENT LENGTHS. IF YOU DO NOT INSTALL EACH OF THE SCREWS IN ITS CORRECT POSITION, YOU CAN CAUSE DAMAGE.
   (1) Put the pressure relief door (1) in position.
   (2) Apply Polysulfide Sealant-Fuel Tank Fillet 120 degre Celsius (Material No.06ABB2) on the shanks of the screws (2), (3), (4) and (5).
   (3) Install the screws (2), (3), (4) and (6) and the nuts (8), (9), (11) and (12).
   (4) Install the screw (5), the bonding lead (7) and the nut (10).
   (5) When you install the screw (5) and the nut (10), do the electrical bonding at the applicable location (Ref. AMM TASK 20-28-00-912-802).
   (6) Tighten the nuts (8), (9), (10), (11) and (12).
   (7) Close the pressure relief door (1).
Subtask 54-53-11-820-052-A
B. Check of the Clearance
   (1) Make sure that out-of-flush dimension A1 between the pressure relief door (1) and the overpressure access door (2) is 0 +0 mm or -1.1 mm (0.0000 +0.0000 in. or -0.0433 in.).
   (2) Make sure that peripheral clearance J1 between the pressure relief door (1) and the overpressure access door (2) is 3 +2 mm or -2 mm (0.1181 +0.0787 in. or -0.0787 in.).
5. Close-up
Subtask 54-53-11-440-060-A
A. Reactivation of the Thrust Reverser
   (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-807).
Subtask 54-53-11-942-059-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
   (3) Remove the warning notice(s).
[Rev.10 from 2021] 2026.04.01 02:02:37 UTC