W DOC AIRBUS | AMM A320F

Replacement of the Fire Seals of the Pylon-to-Wing Center Fillets


TASK 54-53-11-300-802-A
Replacement of the Fire Seals of the Pylon-to-Wing Center Fillets


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 410
ZONE: 420
ZONE: 470
ZONE: 480
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
1
MAT - PROTECTIVE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
410
ENG 1 PYLON BOX AND FORWARD FAIRING
420
ENG 2 PYLON BOX AND FORWARD FAIRING
470
ENGINE 1 AFT PYLON
480
ENGINE 2 AFT PYLON
413ET, 423ET, 471AL, 471BL, 471CL, 472AR, 472BR, 481AL, 481BL, 482AR, 482BR, 482CR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 54-53-11-000-806-A
Removal of the Pylon-to-Wing Access Panels and Doors
TASK 54-53-11-400-806-A
Installation of the Pylon-to-Wing Access Panels and Doors
TASK 78-30-00-040-807-A
Deactivation of the Thrust Reverser System for Nacelle Maintenance (ICU)
TASK 78-30-00-440-807-A
Reactivation of the Thrust Reverser System after Nacelle Maintenance (ICU)
3. Job Set-up
Subtask 54-53-11-941-068-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put a WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 54-53-11-040-070-A
B. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-807).
Subtask 54-53-11-010-064-A
C. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) For the left pylon, in zones 410 and 470
     (b) For the right pylon, in zones 420 and 480.
   (2) Remove the pylon-to-wing access panels and doors (Ref. AMM TASK 54-53-11-000-806):
     (a) For the left pylon: 413ET 471AL 471BL 471CL 472AR and 472BR
     (b) For the right pylon: 423ET 481AL 481BL 482AR 482BR and 482CR.
4. Procedure
Subtask 54-53-11-300-051-A
A. Replacement of the Fire Seals of the Pylon-to-Wing Center Fillets
NOTE: The procedure is the same for all pylon-to-wing access panels and doors.
   (1) Put the pylon-to-wing access panel/door (2) on a MAT - PROTECTIVE.
   (2) Remove the used seal (1) from the pylon-to-wing access panel/door (2).
   (3) Install a new seal (1).
   (4) Make sure that the seal is correctly assembled in its groove and that it has the correct orientation. To do this:
     (a) Make sure that the seal marking is on the internal side of the panel.
     (b) Make sure that the seal stop touches the seal retainer lip.
5. Close-up
Subtask 54-53-11-410-055-A
A. Close Access
   (1) Install the pylon-to-wing access panels and doors (Ref. AMM TASK 54-53-11-400-806):
     (a) For the left pylon: 413ET 471AL 471BL 471CL 472AR and 472BR
     (b) For the right pylon: 423ET 481AL 481BL 482AR 482BR and 482CR.
Subtask 54-53-11-440-063-A
B. Reactivation of the Thrust Reverser
   (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-807).
Subtask 54-53-11-942-062-A
C. Aircraft Maintenance Configuration
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).