W DOC AIRBUS | AMM A320F

Detailed Inspection of Karman Fairing Fire Seals


TASK 54-50-00-220-802-A
Detailed Inspection of Karman Fairing Fire Seals


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 470
ZONE: 480
FIN: 4020KM1 ** ON A/C NOT FOR ALL
FIN: 4020KM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 545900-W3
DETAILED INSPECTION OF KARMAN FAIRING FIRE SEALS.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
470
ENGINE 1 AFT PYLON
480
ENGINE 2 AFT PYLON
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 54-53-11-300-801-A
Replacement of the Fire Seals of the Pylon-to-Wing Center Fillets
TASK 54-54-11-300-801-A
Replacement of the Fire Seals of the Rear Pylon Fairing (RPF)
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-30-00-440-805-A
Reactivation of the Thrust Reverser System after Ground Maintenance
3. Job Set-up
Subtask 54-50-00-941-073-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 54-50-00-040-064-A ** ON A/C NOT FOR ALL
B. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 54-50-00-010-063-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) For the left pylon, in zone 470
     (b) For the right pylon, in zone 480.
Subtask 54-50-00-160-050-A ** ON A/C NOT FOR ALL
D. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure
Subtask 54-50-00-220-054-A ** ON A/C NOT FOR ALL
A. Inspection of the Karman Fairing Fire-Seals
F Karman Fairing Fire-Seals ** ON A/C NOT FOR ALL
   (1) Do a detailed inspection of the Karman fairing fire-seals.
   (2) Make sure that there is no wear, damage or deterioration.
   (3) If you find wear, damage or deterioration, replace the damaged seals:
     (a) For the fire seals of the pylon-to-wing center fillets (Ref. AMM TASK 54-53-11-300-801).
     (b) For the fire seals of the Rear Pylon Fairing (RPF) (Ref. AMM TASK 54-54-11-300-801).
5. Close-up
Subtask 54-50-00-440-060-A ** ON A/C NOT FOR ALL
A. Reactivation of the Thrust Reverser
   (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 54-50-00-410-062-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 01:59:12 UTC