Detailed Visual Inspection of AFT Cargo Compartment Door (Internal Hinge Fittings Attachment Area)
TASK 52-32-11-200-004-A
Detailed Visual Inspection of AFT Cargo Compartment Door (Internal Hinge Fittings Attachment Area)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-32-11-010-053-A ** ON A/C NOT FOR ALL
Subtask 52-32-11-210-054-A ** ON A/C NOT FOR ALL
Subtask 52-32-11-865-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:42:06 UTC
Detailed Visual Inspection of AFT Cargo Compartment Door (Internal Hinge Fittings Attachment Area)
ZONE: 826
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 826 | AFT CARGO COMPARTMENT DOOR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 51-75-12-300-001-A | Repair of Major Paint Damage on Light Alloy and Composite Material |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-32-13-000-001-A | Removal of the Lining and Insulation |
| TASK 52-32-13-400-001-A | Installation of the Lining and Insulation |
| SRM 517300 | |
| SRM 517400 | |
| SRM 523000 | |
Subtask 52-32-11-010-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Open the AFT cargo door and safety it with the actuator safety locks (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the opened cargo door.
(3) Remove the lining and the insulation of the cargo door (Ref. AMM TASK 52-32-13-000-001).
Subtask 52-32-11-865-056-A ** ON A/C NOT FOR ALL (1) Open the AFT cargo door and safety it with the actuator safety locks (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the opened cargo door.
(3) Remove the lining and the insulation of the cargo door (Ref. AMM TASK 52-32-13-000-001).
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | DOORS/CARGO | 1MJ | T12 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
Subtask 52-32-11-210-054-A ** ON A/C NOT FOR ALL
A. Visual Inspection of the inner Attachment Area of the Piano Hinge Fittings
(1) Examine the upper door structure from the inner side for corrosion and cracks.
(a) If you find corrosion,
(2) Make sure that the Hi-Lok rivets are correctly tightened.
(3) Make sure that the attachment screws and nuts of the piano hinge fittings are correctly tightened and not damaged.
(4) Make sure that the paint coat in the internal attachment area is in the correct condition (Ref. AMM TASK 51-75-12-300-001).
5. Close-up(1) Examine the upper door structure from the inner side for corrosion and cracks.
(a) If you find corrosion,
- determine the extent of the corroded area SRM 523000,
- remove the damage when it is less than the limit SRM 517400.
NOTE: When the corroded area is larger than the limit, repair the affected internal attachment area.
(b) If you find a crack, repair it immediately SRM 517300. (2) Make sure that the Hi-Lok rivets are correctly tightened.
(3) Make sure that the attachment screws and nuts of the piano hinge fittings are correctly tightened and not damaged.
(4) Make sure that the paint coat in the internal attachment area is in the correct condition (Ref. AMM TASK 51-75-12-300-001).
Subtask 52-32-11-865-057-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-32-11-410-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | DOORS/CARGO | 1MJ | T12 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the lining and the insulation of the cargo door (Ref. AMM TASK 52-32-13-400-001).
(3) Remove the actuator safety locks and close the AFT cargo door (Ref. AMM TASK 52-30-00-860-002).
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the lining and the insulation of the cargo door (Ref. AMM TASK 52-32-13-400-001).
(3) Remove the actuator safety locks and close the AFT cargo door (Ref. AMM TASK 52-30-00-860-002).
(4) Remove the access platform(s).
Inspection of the Internal Attachment Area of the Piano Hinge Fittings