W DOC AIRBUS | AMM A320F

Removal of the Water Faucet


TASK 38-12-41-000-001-A
Removal of the Water Faucet


NOTE: The procedure for the removal of the water faucet and the mixing timer is the same in all lavatories.
ZONE: 200
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ALLEN KEY - DRIVER PNR ISO 2936-2.5
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 38-10-00-614-002-A
Depressurization of the Potable Water System
F Wash Basin Faucet ** ON A/C NOT FOR ALL
F Wash Basin Faucet ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 38-12-41-861-060-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-12-41-614-051-A ** ON A/C NOT FOR ALL
B. Depressurize the potable water system (Ref. AMM TASK 38-10-00-614-002).
Subtask 38-12-41-010-050-C ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the lavatory door.
   (2) Open the access door to the potable-water shutoff valve.
   (3) Close the potable-water shutoff valve.
   (4) Put the WARNING NOTICE(S) in position to tell persons not to open the potable-water shutoff valve.
Subtask 38-12-41-865-076-A ** ON A/C NOT FOR ALL
D. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2000VULAV FWD-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-G9MBB03
2001VULAV AFT-HOT WATER-D/F2MBB02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER9MBB03
2001VULAV AFT-HOT WATER2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E/L9MBB03
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-L9MBC04
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D/L2MBB02
Subtask 38-12-41-680-050-C ** ON A/C NOT FOR ALL
E. Operate the water faucet until no water flows into the washbasin.
4. Procedure
Subtask 38-12-41-020-050-D ** ON A/C NOT FOR ALL
A. Removal of the Water Faucet
F Wash Basin Faucet ** ON A/C NOT FOR ALL
   (1) Remove the screw(s) (2) with an ALLEN KEY - DRIVER PNR ISO 2936-2.5.
   (2) Carefully pull the water faucet (1) away from the wash basin (4).
   (3) Remove and discard the O-rings (5).
   (4) Remove the washers (6).
   (5) Carefully pull the hose assemblies (3) away from the wash basin (4).
   (6) Disconnect the connections (9) from the fittings (10).
   (7) Loosen the nuts (8) but do not remove them.
   (8) Move the fittings (10) away from the brackets (7) and (11).
   (9) Remove the hose assemblies (3).
   (10) Put the PLUG-BLANKING in each disconnected line end.
Subtask 38-12-41-020-050-N ** ON A/C NOT FOR ALL
A. Removal of the Water Faucet
F Wash Basin Faucet ** ON A/C NOT FOR ALL
   (1) Remove the screw(s):
     (a) In the lavatory:
  • Remove the screws (2) with an ALLEN KEY - DRIVER PNR ISO 2936-2.5.
     (b) In the smart lavatory:
  • Remove the screw (3).
     (c) In the space flex lavatory:
  • Remove the screw (3).
   (2) Carefully pull the water faucet (1) away from the wash basin (5).
   (3) Remove and discard the packings (6).
   (4) Remove the retaining washers (7).
   (5) Carefully pull the hose assemblies (4) away from the wash basin (5).
   (6) Disconnect the connections (12) from the fittings (10).
   (7) Loosen the nuts (11) but do not remove them.
   (8) Move the hose assemblies (4) with the fittings (10) away from the brackets (8) and (13).
   (9) Remove the fittings (10):
     (a) Disconnect the fittings (10) from the hose assemblies (4) and remove them.
     (b) Remove the filters (9).
   (10) Put the PLUG-BLANKING in each disconnected line end.