OXY High Pressure Indication-Direct Reading


TASK 35-10-00-040-001-A
OXY High Pressure Indication-Direct Reading


1. Reason for the Job
MMEL 35-07-01A
CREW OXY HIGH PRESSURE INDICATION ON THE DOOR/OXY SD PAGE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
THERMOMETER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
812
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 12-14-35-600-001-A
Servicing of the Oxygen-Replenishing
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 35-10-00-861-051-A
A. Energize the Ground Service Network (Ref. AMM TASK 24-42-00-861-001).
Subtask 35-10-00-010-053-A
B. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE at access door 812.
   (2) Open access door 812.
4. Procedure
Subtask 35-10-00-220-052-C ** ON A/C NOT FOR ALL
A. Check of the High Pressure of the Crew Oxygen-Storage Cylinder
   (1) Do a check of the oxygen pressure on the direct-reading pressure gage of the crew oxygen-storage cylinder (5750HM).
     (a) Record the oxygen pressure of the crew oxygen-storage cylinder (5750HM).
   (2) Measure the Outside Air Temperature (OAT) and the temperature in the cockpit with a THERMOMETER.
   (3) Calculate the reference temperature with this formula:
OAT + COCKPIT TEMPERATURE
-------------------------
2

   (4) Record the reference temperature.
   (5) Send the recorded values to the crew.
   (6) After the crew uses the Flight Crew Operating Manual (FCOM), if the oxygen pressure recorded at Step 4.A.(1).(a) is less than the minimum oxygen pressure found in the FCOM table:
Subtask 35-10-00-220-052-E ** ON A/C NOT FOR ALL
A. Check of the High Pressure of the Crew Oxygen-Storage Cylinders
   (1) Do a check of the oxygen pressure on the direct-reading pressure gage of the crew oxygen-storage cylinders 5750HM1 and 5750HM2.
     (a) Record the oxygen pressure of the crew oxygen-storage cylinder 5750HM1 and record that this value is related to the Captain system.
     (b) Record the oxygen pressure of the crew oxygen-storage cylinder 5750HM2 and record that this value is related to the First Officer system.
   (2) Measure the Outside Air Temperature (OAT) and the temperature in the cockpit with a THERMOMETER.
   (3) Calculate the reference temperature with this formula:
OAT + COCKPIT TEMPERATURE
-------------------------
2

   (4) Record the reference temperature.
   (5) Send the recorded values to the crew.
   (6) After the crew uses the Flight Crew Operating Manual (FCOM), if the oxygen pressure(s) recorded at Step 4.A.(1) is (are) less than the minimum oxygen pressure(s) found in the FCOM table:
5. Close-up
Subtask 35-10-00-410-053-A
A. Close Access
   (1) Close access door 812.
   (2) Remove the access platform(s).
   (3) Make an entry in the logbook.
Subtask 35-10-00-862-051-A
B. De-energize the Ground Service Network (Ref. AMM TASK 24-42-00-862-001).