Inspection of the Static Port and Standby Static Port
TASK 34-11-16-200-001-A
Inspection of the Static Port and Standby Static Port
To do a visual inspection of the static port and standby static port.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-11-16-865-059-A
Subtask 34-11-16-220-050-A ** ON A/C NOT FOR ALL
Subtask 34-11-16-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 04:08:04 UTC
Inspection of the Static Port and Standby Static Port
WARNING:
MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
WARNING:
MAKE SURE THAT:
1. Reason for the Job- THE STATIC PROBE IS NOT HOT
- THE ELECTRICAL SUPPLY TO THE HEATING ELEMENT OF THE PROBE IS ISOLATED
To do a visual inspection of the static port and standby static port.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| FOR [7DA1] (PROBE-L STATIC, 1) | ||
| FOR [7DA2] (PROBE-L STATIC, 2) | ||
| FOR [8DA1] (PROBE-R STATIC, 1) | ||
| FOR [8DA2] (PROBE-R STATIC, 2) | ||
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| FOR [7DA3] (PROBE-L STATIC, 3) | ||
| FOR [8DA3] (PROBE-R STATIC, 3) | ||
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| FOR [7DA1] (PROBE-L STATIC, 1) | |
| FOR [7DA2] (PROBE-L STATIC, 2) | |
| FOR [8DA1] (PROBE-R STATIC, 1) | |
| FOR [8DA2] (PROBE-R STATIC, 2) | |
| TASK 34-10-00-170-002-A | Flushing of the Principal Static Pressure Lines |
| SRM 530011 | |
| SRM 531111 | |
| FOR [7DA3] (PROBE-L STATIC, 3) | |
| FOR [8DA3] (PROBE-R STATIC, 3) | |
| TASK 34-10-00-170-003-A | Draining and Flushing of Standby Pneumatic Circuits |
| TASK 34-22-25-170-001-A | Draining and Flushing of Standby Pneumatic Circuits |
| TASK 53-19-42-000-001-A | Removal of the Static Port Blanking-Plate |
| TASK 53-19-42-400-001-A | Installation of the Static Port Blanking-Plate |
| SRM 530011 | |
| SRM 531111 | |
Subtask 34-11-16-865-059-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 34-11-16-010-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 8DA1 (PROBER STATIC, 1) FOR FIN: 7DA1 (PROBEL STATIC, 1) | |||
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| FOR FIN: 8DA2 (PROBER STATIC, 2) FOR FIN: 7DA2 (PROBEL STATIC, 2) | |||
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| FOR FIN: 8DA3 (PROBER STATIC, 3) FOR FIN: 7DA3 (PROBEL STATIC, 3) | |||
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
B. Get Access
(1) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
Subtask 34-11-16-010-051-B ** ON A/C NOT FOR ALL (1) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
- Put an ACCESS PLATFORM 1M(3 FT) in position at the zone 128.
- Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the zone 120.
B. Get Access
(1) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
4. Procedure(1) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
- Put an ACCESS PLATFORM 1M(3 FT) in position at the zone 128.
- Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the zone 120.
Subtask 34-11-16-220-050-A ** ON A/C NOT FOR ALL
A. Inspection of the Static Ports
(1) Remove the cover of the static probes.
(2) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
(a) Do a visual check of the principal static ports:
(a) Do a visual check of the standby static ports:
Subtask 34-11-16-220-050-B ** ON A/C NOT FOR ALL (1) Remove the cover of the static probes.
(2) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
(a) Do a visual check of the principal static ports:
- If there is contamination, do the flushing of the principal static pressure-lines (Ref. AMM TASK 34-10-00-170-002).
- If there are signs of lightning strikes (burn marks, spots, etc.) on one of the static ports, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011 or if the repair is not given in the Structural Repair Manual (SRM), contact the Airbus Customer Services department.
- If there is damage, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011, do the repair given in the procedure SRM 531111.
(a) Do a visual check of the standby static ports:
- If there is contamination, do the draining and the flushing of the standby static pressure-lines (Ref. AMM TASK 34-10-00-170-003).
- If there is a damage, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011 or if the repair is not given in the SRM, contact the Airbus Customer Services department.
- If there is damage, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011, do the repair given in the procedure SRM 531111.
A. Inspection of the Static Ports
(1) Remove the cover of the static probes.
(2) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
(a) Do a visual check of the principal static ports:
(a) Do a visual check of the standby static ports:
1 If there is a damage or if the surface of the blanking plate of the standby static port is not smooth, refer to the procedure SRM 530011 for the allowable damage criteria.
a If the signs of damage are out of the tolerances given in the procedure SRM 530011:
Subtask 34-11-16-220-050-D ** ON A/C NOT FOR ALL (1) Remove the cover of the static probes.
(2) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
(a) Do a visual check of the principal static ports:
- If there is contamination, do the flushing of the principal static pressure-lines (Ref. AMM TASK 34-10-00-170-002).
- If there are signs of lightning strikes (burn marks, spots, etc.) on one of the static ports, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011 or if the repair is not given in the Structural Repair Manual (SRM), contact the Airbus Customer Services department.
- If there is damage, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011, do the repair given in the procedure SRM 531111.
(a) Do a visual check of the standby static ports:
- If there is contamination, do the draining and the flushing of the standby static pressure-lines (Ref. AMM TASK 34-10-00-170-003).
- If there is a damage, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011 or if the repair is not given in the Structural Repair Manual (SRM), contact the Airbus Customer Services department.
1 If there is a damage or if the surface of the blanking plate of the standby static port is not smooth, refer to the procedure SRM 530011 for the allowable damage criteria.
a If the signs of damage are out of the tolerances given in the procedure SRM 530011:
- Replace the blanking plate of the standby static port (Ref. AMM TASK 53-19-42-000-001) and (Ref. AMM TASK 53-19-42-400-001).
- Do the repair given in the procedure SRM 531111.
A. Inspection of the Static Ports
(1) Remove the cover of the static probes.
(2) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
(a) Do a visual check of the principal static ports:
(a) Do a visual check of the standby static ports:
1 If there is damage or if the surface of the blanking plate of the standby static port is not smooth, refer to the procedure SRM 530011 for the allowable damage criteria.
a If the signs of damage are out of the tolerances given in the procedure SRM 530011:
5. Close-up(1) Remove the cover of the static probes.
(2) FOR [7DA1] (PROBE-L STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA1] (PROBE-R STATIC, 1), [8DA2] (PROBE-R STATIC, 2)
(a) Do a visual check of the principal static ports:
- If there is contamination, do the flushing of the principal static pressure-lines (Ref. AMM TASK 34-10-00-170-002).
- If there are signs of lightning strikes (burn marks, spots, etc.) on one of the static ports, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011 or if the repair is not given in the Structural Repair Manual (SRM), contact the Airbus Customer Services department.
- If there is damage, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011, do the repair given in the procedure SRM 531111.
(a) Do a visual check of the standby static ports:
- If there is contamination, do the draining and the flushing of the standby static pressure-lines (Integrated Standby Instrument System (ISIS)) (Ref. AMM TASK 34-22-25-170-001).
- If there is a damage, refer to the procedure SRM 530011 for the allowable damage criteria.
- If the signs of damage are out of the tolerances given in the procedure SRM 530011 or if the repair is not given in the SRM, contact the Airbus Customer Services department.
1 If there is damage or if the surface of the blanking plate of the standby static port is not smooth, refer to the procedure SRM 530011 for the allowable damage criteria.
a If the signs of damage are out of the tolerances given in the procedure SRM 530011:
- Replace the blanking plate of the standby static port (Ref. AMM TASK 53-19-42-000-001) and (Ref. AMM TASK 53-19-42-400-001).
- Do the repair given in the procedure SRM 531111.
Subtask 34-11-16-410-053-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the cover of the static probes.
(3) Remove the access platform(s).
Subtask 34-11-16-410-053-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the cover of the static probes.
(3) Remove the access platform(s).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the cover of the static probes.
(3) Remove the access platform(s).
Subtask 34-11-16-865-060-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the cover of the static probes.
(3) Remove the access platform(s).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 8DA1 (PROBER STATIC, 1) FOR FIN: 7DA1 (PROBEL STATIC, 1) | |||
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| FOR FIN: 8DA2 (PROBER STATIC, 2) FOR FIN: 7DA2 (PROBEL STATIC, 2) | |||
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| FOR FIN: 8DA3 (PROBER STATIC, 3) FOR FIN: 7DA3 (PROBEL STATIC, 3) | |||
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |