Removal of the Static Port Blanking-Plate
TASK 53-19-42-000-001-A
Removal of the Static Port Blanking-Plate
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 53-19-42-865-050-A ** ON A/C NOT FOR ALL
Subtask 53-19-42-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:52:15 UTC
Removal of the Static Port Blanking-Plate
WARNING:
BEFORE YOU OPEN PHC CIRCUIT BREAKERS 2DA1(2,3), OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE:
- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
WARNING:
MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
WARNING:
MAKE SURE THAT:
- THE STATIC PROBE IS NOT HOT
- THE ELECTRICAL SUPPLY TO THE HEATING ELEMENT OF THE PROBE IS ISOLATED
ZONE: 120
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | SCRAPER - NON METALLIC |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 53-19-42-865-050-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 53-19-42-941-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zone 120.
Subtask 53-19-42-860-051-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zone 120.
C. Aircraft Maintenance Configuration
(1) Remove the protective covers from the static probes.
4. Procedure(1) Remove the protective covers from the static probes.
Subtask 53-19-42-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Static Port Blanking-Plate
(1) Use the SCRAPER - NON METALLIC to remove the sealants from the area between the static port blanking-plate (3) and the fuselage structure.
(2) Remove the screws (1) and (2).
(3) Remove the static port blanking-plate (3).
(1) Use the SCRAPER - NON METALLIC to remove the sealants from the area between the static port blanking-plate (3) and the fuselage structure.
(2) Remove the screws (1) and (2).
(3) Remove the static port blanking-plate (3).
Installation of the Static Port Blanking-Plate