Installation of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
TASK 33-51-21-400-001-A
Installation of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 33-51-21-860-051-A ** ON A/C NOT FOR ALL
Subtask 33-51-21-910-050-D ** ON A/C NOT FOR ALL
Subtask 33-51-21-860-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:57:40 UTC
Installation of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | SCRAPER - NON METALLIC |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.06BQD1) | Silicone Sealant-Non Textile Floor Jointing One part - |
| (Material No.06CMD9) | Silicone Adhesive Sealant-General Purpose One part legacy |
| (Material No.06PBG1) | Adhesion Promoter-For Silicone Sealant - - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| No specific | ADHESIVE TAPE - DAN382-50 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 33-51-21-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 33-51-21-910-050-D ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Do an inspection of the component interfaces and the adjacent area.
Subtask 33-51-21-910-050-E ** ON A/C NOT FOR ALL (1) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Do an inspection of the component interfaces and the adjacent area.
A. Preparation for Installation
Photoluminescent Strip (Floor Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Remove the sealant (2) with a SCRAPER - NON METALLIC.
(2) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 33-51-21-910-050-F ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL (2) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(3) Do an inspection of the component interfaces and the adjacent area.
A. Preparation for Installation
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Remove the sealant (4) with a SCRAPER - NON METALLIC.
(2) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 33-51-21-910-050-N ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL (2) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(3) Do an inspection of the component interfaces and the adjacent area.
A. Preparation for Installation
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Remove the sealant (6) with a SCRAPER - NON METALLIC.
(2) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 33-51-21-910-050-O ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL (2) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(3) Do an inspection of the component interfaces and the adjacent area.
A. Preparation for Installation
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Remove the sealant (6) with a SCRAPER - NON METALLIC.
(2) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a lint free cloth Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 33-51-21-420-050-A ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL (2) Clean the component interface and/or the adjacent area on the floor panels with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a lint free cloth Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Cut the photoluminescent strips (1) and (5) to length.
(3) Align the self-adhesive photoluminescent strips (1) and (5) and install them with a Textile-Lint free Cotton - (Material No.14SBA1) .
(4) Use light hand pressure from one end of the strip to the other to install the photoluminescent strips (1) and (5) correctly.
(5) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) between the edges of the photoluminescent strips (1) and the non-textile floor-covering.
(6) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (2) between the edges of the photoluminescent strips (1) and the non-textile floor-covering.
Subtask 33-51-21-420-050-H ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL NOTE: There must be a distance of 2.0 mm (0.0787 in.) between the photoluminescent strips (1) and (5) and the adjacent photoluminescent strips.
(2) Remove the protective foil from the photoluminescent strips (1) and (5). (3) Align the self-adhesive photoluminescent strips (1) and (5) and install them with a Textile-Lint free Cotton - (Material No.14SBA1) .
(4) Use light hand pressure from one end of the strip to the other to install the photoluminescent strips (1) and (5) correctly.
(5) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) between the edges of the photoluminescent strips (1) and the non-textile floor-covering.
(6) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (2) between the edges of the photoluminescent strips (1) and the non-textile floor-covering.
B. Installation of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
Photoluminescent Strip (Floor Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Install the ADHESIVE TAPE - DAN382-50 (3) on the floor panel.
(2) If you removed the end-cap, install it on the photoluminescent strip (1).
(3) If necessary, apply Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) on the end-cap (6).
(4) Cut the photoluminescent strip (1) to the correct length.
(6) Remove the protective foil from the photoluminescent strip (1).
(7) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) on the length of the photoluminescent strip (1).
(8) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) to the edges of the photoluminescent strip (1) and the non-textile floor covering.
(9) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (2) to the edges of the photoluminescent strip (1) and the non-textile floor covering.
(10) Install the carpet protector (7) and make sure that it engages correctly.
(11) Make sure that the end(s) of the carpet protector (7) has (have) a distance of 2.0 mm (0.0787 in.) from the opposite end(s) of the next carpet protector(s) (7).
Subtask 33-51-21-420-050-AR ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL (2) If you removed the end-cap, install it on the photoluminescent strip (1).
(3) If necessary, apply Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) on the end-cap (6).
(4) Cut the photoluminescent strip (1) to the correct length.
NOTE: There is a distance of 2.0 mm (0.0787 in.) between the photoluminescent strip (1) and the adjacent photoluminescent strips.
(5) Cut the carpet protector (7) to the correct length. (6) Remove the protective foil from the photoluminescent strip (1).
(7) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) on the length of the photoluminescent strip (1).
(8) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) to the edges of the photoluminescent strip (1) and the non-textile floor covering.
(9) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (2) to the edges of the photoluminescent strip (1) and the non-textile floor covering.
(10) Install the carpet protector (7) and make sure that it engages correctly.
(11) Make sure that the end(s) of the carpet protector (7) has (have) a distance of 2.0 mm (0.0787 in.) from the opposite end(s) of the next carpet protector(s) (7).
B. Installation of the Photoluminescent Strips of the Floor-Proximity Emergency-Escape Path-Marking
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Install the photoluminescent strips (3) and (5) as follows:
(a) Cut the photoluminescent strips (3) and (5) to their correct length.
(c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the photoluminescent strip (3) and (5).
(d) Make sure that the photoluminescent strips (3) and (5) are correctly installed.
(2) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) to the edges of the photoluminescent strip (5) and the non-textile floor covering.
(3) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (6) to the edges of the photoluminescent strip (5) and the non-textile floor covering.
(4) Cut the filter films (2) to length and put them in position on the photoluminescent strip (3).
(5) Install the clips (1) on the photoluminescent strip (3).
(6) Install the end-cap clips (4) and the end-caps (7).
(7) If necessary, apply Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) on the end-cap clips (4) and the end-caps (7).
Subtask 33-51-21-420-050-AV ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL (a) Cut the photoluminescent strips (3) and (5) to their correct length.
NOTE: There is a distance of 2.0 mm (0.0787 in.) between the ends of the photoluminescent strip.
(b) Remove the protective foil from the photoluminescent strips (3) and (5). (c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the photoluminescent strip (3) and (5).
(d) Make sure that the photoluminescent strips (3) and (5) are correctly installed.
(2) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) to the edges of the photoluminescent strip (5) and the non-textile floor covering.
(3) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (6) to the edges of the photoluminescent strip (5) and the non-textile floor covering.
(4) Cut the filter films (2) to length and put them in position on the photoluminescent strip (3).
(5) Install the clips (1) on the photoluminescent strip (3).
(6) Install the end-cap clips (4) and the end-caps (7).
(7) If necessary, apply Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) on the end-cap clips (4) and the end-caps (7).
B. Installation of the Photoluminescent Strips of the Floor-Proximity Emergency-Escape Path-Marking
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Install the filler (4) as follows:
(a) Cut the filler (4) to the correct length.
(c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the filler (4).
(2) Install the photoluminescent strips (2) and (5) as follows:
(a) Cut the photoluminescent strips (2) and (5) to their correct length.
(c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the photoluminescent strips (2) and (5).
(d) Make sure that the photoluminescent strips (2) and (5) are correctly installed.
(3) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) to the edges of the photoluminescent strips (2) and (5) and the non-textile floor covering.
(4) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (6) to the edges of the photoluminescent strips (2) and (5) and the non-textile floor covering.
(5) Install the clips (1) on the photoluminescent strip (2).
(6) Install the end-cap clips (3) and the end-caps (7).
(7) If necessary, apply Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) on the end-cap clips (3) and the end-caps (7).
Subtask 33-51-21-420-050-AW ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL (a) Cut the filler (4) to the correct length.
NOTE: There is a distance of 2.0 mm (0.0787 in.) between the filler (4) and the adjacent filler.
(b) Remove the protective foil from the filler (4). (c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the filler (4).
(2) Install the photoluminescent strips (2) and (5) as follows:
(a) Cut the photoluminescent strips (2) and (5) to their correct length.
NOTE: There is a distance of 2.0 mm (0.0787 in.) between the ends of the photoluminescent strips.
(b) Remove the protective foil from the photoluminescent strips (2) and (5). (c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the photoluminescent strips (2) and (5).
(d) Make sure that the photoluminescent strips (2) and (5) are correctly installed.
(3) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) to the edges of the photoluminescent strips (2) and (5) and the non-textile floor covering.
(4) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (6) to the edges of the photoluminescent strips (2) and (5) and the non-textile floor covering.
(5) Install the clips (1) on the photoluminescent strip (2).
(6) Install the end-cap clips (3) and the end-caps (7).
(7) If necessary, apply Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) on the end-cap clips (3) and the end-caps (7).
B. Installation of the Photoluminescent Strips of the Floor-Proximity Emergency-Escape Path-Marking
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Install the filler (4) as follows:
(a) Cut the filler (4) to the correct length.
(c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the filler (4).
(2) Install the photoluminescent strip (3) as follows:
(a) Cut the photoluminescent strip (3) to the correct length.
(c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the photoluminescent strip (3).
(d) Make sure that the photoluminescent strip (3) is correctly installed.
(3) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) to the edges of the photoluminescent strip (3) and the non-textile floor covering.
(4) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (6) to the edges of the photoluminescent strip (3) and the non-textile floor covering:
(a) If necessary, cut the filter films (2) to the correct length and put it in position on the photoluminescent strip (3).
(b) Install the clips (1) and the end-cap clips (5).
(c) If necessary, apply Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) on the end-cap clips (5).
Subtask 33-51-21-420-050-AZ ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL (a) Cut the filler (4) to the correct length.
NOTE: There is a distance of 2.0 mm (0.0787 in.) between the filler (4) and the adjacent filler.
(b) Remove the protective foil from the filler (4). (c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the filler (4).
(2) Install the photoluminescent strip (3) as follows:
(a) Cut the photoluminescent strip (3) to the correct length.
NOTE: There is a distance of 2.0 mm (0.0787 in.) between the ends of the photoluminescent strips.
(b) Remove the protective foil from the photoluminescent strip (3). (c) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) to the length of the photoluminescent strip (3).
(d) Make sure that the photoluminescent strip (3) is correctly installed.
(3) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) to the edges of the photoluminescent strip (3) and the non-textile floor covering.
(4) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (6) to the edges of the photoluminescent strip (3) and the non-textile floor covering:
(a) If necessary, cut the filter films (2) to the correct length and put it in position on the photoluminescent strip (3).
(b) Install the clips (1) and the end-cap clips (5).
(c) If necessary, apply Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) on the end-cap clips (5).
B. Installation of the Photoluminescent Strips of the Floor-Proximity Emergency-Escape Path-Marking
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Install the filler (3):
(b) Cut the filler (3) to the correct length.
(c) Remove the protective foil from the filler (3).
(d) Align the filler (3) and install it with a Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Install the photoluminescent strip (1):
(a) Between the ends of the photoluminescent strips (1) must be a distance of 2.0 mm (0.0787 in.).
(b) Cut the photoluminescent strip (1) to the correct length.
(c) Remove the protective foil from the photoluminescent strip (1).
(d) Align the photoluminescent strip (1) and install them with a Textile-Lint free Cotton - (Material No.14SBA1) . Do the installation with light hand pressure from one end of the photoluminescent strip (1) to the other.
(e) Make sure that the photoluminescent strip (1) is correctly installed.
(3) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (2) between the photoluminescent strip (1) and the non-textile floor-covering.
Subtask 33-51-21-420-050-BW ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
Photoluminescent Strip (Floor-Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL NOTE: The filler is only necessary for flush installation of the photoluminescent strips with the floor covering.
(a) Between the ends of the filler (3) must be a distance of 2.0 mm (0.0787 in.). (b) Cut the filler (3) to the correct length.
(c) Remove the protective foil from the filler (3).
(d) Align the filler (3) and install it with a Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Install the photoluminescent strip (1):
(a) Between the ends of the photoluminescent strips (1) must be a distance of 2.0 mm (0.0787 in.).
(b) Cut the photoluminescent strip (1) to the correct length.
(c) Remove the protective foil from the photoluminescent strip (1).
(d) Align the photoluminescent strip (1) and install them with a Textile-Lint free Cotton - (Material No.14SBA1) . Do the installation with light hand pressure from one end of the photoluminescent strip (1) to the other.
(e) Make sure that the photoluminescent strip (1) is correctly installed.
(3) Apply Silicone Sealant-Non Textile Floor Jointing One part - (Material No.06BQD1) (2) between the photoluminescent strip (1) and the non-textile floor-covering.
B. Installation of the Photoluminescent Strips of the Floor-Proximity Emergency-Escape Path-Marking
Photoluminiscent Strip (Floor Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL
(1) Install the filler (3):
(a) Between the ends of the filler (3) there must be a distance of 2.0 mm (0.0787 in.).
(b) Cut the filler (3) to the correct length.
(c) Remove the protective foil from the filler (3).
(d) Put the filler (3) in position on the related floor panels with the adhesive-tape face down.
(e) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) along the length of the filler (3).
(2) Install the photoluminescent strip (1):
(a) Between the ends of the photoluminescent strips (1) there must be a distance of 2.0 mm (0.0787 in.).
(b) Cut the photoluminescent strip (1) to the correct length.
(c) Remove the protective foil from the photoluminescent strip (1).
(d) Align the photoluminescent strip (1).
(e) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) along the length of the photoluminescent strip (1).
(f) Make sure that the photoluminescent strip (1) is correctly installed.
(3) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) (2) between the photoluminescent strip (1) and the floor-covering.
5. Close-up
Photoluminiscent Strip (Floor Mounted) of the Floor-Proximity Emergency-Escape Path-Marking ** ON A/C NOT FOR ALL (a) Between the ends of the filler (3) there must be a distance of 2.0 mm (0.0787 in.).
(b) Cut the filler (3) to the correct length.
(c) Remove the protective foil from the filler (3).
(d) Put the filler (3) in position on the related floor panels with the adhesive-tape face down.
(e) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) along the length of the filler (3).
(2) Install the photoluminescent strip (1):
(a) Between the ends of the photoluminescent strips (1) there must be a distance of 2.0 mm (0.0787 in.).
(b) Cut the photoluminescent strip (1) to the correct length.
(c) Remove the protective foil from the photoluminescent strip (1).
(d) Align the photoluminescent strip (1).
(e) Use a Textile-Lint free Cotton - (Material No.14SBA1) and apply a light pressure (with your hand) along the length of the photoluminescent strip (1).
(f) Make sure that the photoluminescent strip (1) is correctly installed.
(3) Apply Adhesion Promoter-For Silicone Sealant - - (Material No.06PBG1) (2) between the photoluminescent strip (1) and the floor-covering.
Subtask 33-51-21-860-052-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).