W DOC AIRBUS | AMM A320F

Deactivation of the Brake Temperature Monitoring-Unit


TASK 32-47-00-040-002-A
Deactivation of the Brake Temperature Monitoring-Unit


ZONE: 210
FIN: 2GW
FIN: 3GW
1. Reason for the Job
MMEL 32-47-01
BRAKE TEMPERATURE MONITORING UNIT (FAA ONLY)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 32-47-00-861-050-A
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 32-47-00-865-059-A
B. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUHYDRAULIC/BRK/TEMP/DET/UNIT1GWM37
4. Procedure
Subtask 32-47-00-040-051-A
A. Deactivation of the Brake Temperature Monitoring-Unit
   (1) Open, safety and tag this(these) circuit breaker(s):
  • 1GW.
5. Close-up
Subtask 32-47-00-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
Subtask 32-47-00-860-053-A
B. Aircraft Maintenance Configuration
   (1) Make an entry in the logbook.
   (2) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 00:50:18 UTC