W DOC AIRBUS | AMM A320F

Removal of the Normal-Brake Supply Pressure-Transducer


TASK 32-42-22-000-001-A
Removal of the Normal-Brake Supply Pressure-Transducer


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
ZONE: 140
FIN: 96GG ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
1
CONTAINER 3 L(3/4 USGAL)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
2
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
140
CENTER WING
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-00-00-910-002-A
Safety Procedures of the Hydraulic System
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
3. Job Set-up
Subtask 32-42-22-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open the left or the right MLG door (Ref. AMM TASK 32-12-00-010-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position.
Subtask 32-42-22-860-050-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Make sure that the Green hydraulic system is depressurized
(Ref. AMM TASK 29-10-00-864-001).
   (2) Depressurize the reservoir of the Green hydraulic system
(Ref. AMM TASK 29-14-00-614-001).
   (3) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system:
  • on the panel 40VU in the cockpit
  • on the ground service panel of the Green hydraulic system.
   (4) Put a CONTAINER 3 L(3/4 USGAL) below the normal-brake supply pressure-transducer (10) to collect the hydraulic fluid leakage.
Subtask 32-42-22-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUABCU &/Y BRK/PRESS IND61GGC10
** ON A/C NOT FOR ALL
49VUHYDRAULIC/G HYD/PUMP ENG1/CTL1701GKH12
** ON A/C NOT FOR ALL
121VUHYDRAULIC/G HYD/PUMP ENG1/CTL1701GKR35
** ON A/C NOT FOR ALL
121VUABCU/HOT BUS/SPLY110GGP30
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR34
** ON A/C NOT FOR ALL
121VUHYDRAULIC/BRAKING AND STEERING/SYS2/SPLY4GGM36
121VUHYDRAULIC/BRAKING AND STEERING/SYS2/CTL3GGM35
121VUHYDRAULIC/BRAKING AND STEERING/SYS1/CTL1GGM34
121VUHYDRAULIC/BRAKING AND STEERING/SYS1/IND AND/SPLY2GGM33
** ON A/C NOT FOR ALL
121VUABCU/HOT BUS/SPLY110GGP31
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR33
4. Procedure
Subtask 32-42-22-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Pressure Transducer (96GG)
   (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
   (2) Disconnect the electrical connector (9).
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (4) Remove the nut (8), the bolt (4), the washer (5) and the bonding strap (6) from the clamp (7).
   (5) Remove the clamp (7) from the pressure transducer (10).
   (6) Hold the pressure transducer (10) and remove the bolts (3) and the washers (2).
   (7) Remove the pressure transducer (10) from the manifold (1).
   (8) Remove and discard the packing (11).
   (9) Install the CAP - BLANKING in the open ports of the pressure transducer (10) and the manifold (1).