W DOC AIRBUS | AMM A320F

Removal of the DMC


TASK 31-63-34-000-001-A
Removal of the DMC


ZONE: 127
ZONE: 128
FIN: 1WT1
FIN: 1WT2
FIN: 1WT3
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
128
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
3. Job Set-up
Subtask 31-63-34-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1WT1 (DMC1)
49VUEIS/DMC1/SPLY10WT1E11
49VUEIS/DMC1/SWTG21WT1E09
** ON A/C NOT FOR ALL
49VUEIS/DMC1/SPLY10WT1E10
49VUEIS/DMC1/SWTG21WT1E08
** ON A/C ALL
FOR FIN: 1WT2 (DMC2)
121VUEIS/DMC2/SPLY10WT2Q08
121VUEIS/DMC2/SWTG21WT2R08
FOR FIN: 1WT3 (DMC3)
49VUEIS/DMC3/SWTG21WT3E07
121VUEIS/DMC3/SPLY10WT3Q09
Subtask 31-63-34-010-050-A
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
   (2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
Subtask 31-63-34-020-050-A
A. Removal of the DMC
   (1) Loosen the nuts (3) on the front of the rack (2).
   (2) Lower the nuts (3).
   (3) Pull the DMC (5) on its rack (2) to disconnect the electrical connectors (1).
   (4) Remove the DMC (5) from its rack (2).
   (5) Put CAP - BLANKING on the electrical connectors (1).
[Rev.10 from 2021] 2026.04.01 04:37:05 UTC