W DOC AIRBUS | AMM A320F

Emergency-Lighting Inhibition With Removal of the Overhead Control and Indicating Panel


TASK 31-14-25-860-002-A
Emergency-Lighting Inhibition With Removal of the Overhead Control and Indicating Panel


ZONE: 210
FIN: 25VU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 31-14-25-862-052-A
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
4. Procedure
Subtask 31-14-25-000-051-A
A. Removal of the Overhead Control and Indicating Panel
   (1) Loosen the four quarter-turn fasteners.
   (2) Pull the panel 25VU from its housing.
   (3) Disconnect the electrical connectors.
   (4) Remove the panel 25VU.
   (5) Put CAP - BLANKING on the disconnected electrical connectors (1), (3), (4) and (5).
   (6) On the connector (2), make a shunt between terminals A and S.
[Rev.10 from 2021] 2026.04.01 00:33:14 UTC